26
MENU 5 (PRE-SELECTIONS)
Txx pre-selec
Select the Txx key for which the
tions key
pre-selection programming is required.
The entry data allowed here is: 1 to12.
MENU 5.1 (TXX PRE-SELECTIONS)
Txx pre-sel. option Entry of the pre-selection option associated
No pre-selection with the Txx key. The entry data allowed here is:
1. No pre-selection :No pre-selection
2. Product absent :Product absent
3. Double product 1:Double product 1
4. Double product 2:Double product 2
5. INC product :product increase
6. DEC product :product decrease
7. Ge. pre-selection :General pre-selection
8. User jug :General user jug
9. Cup :Cup
10. No cup :No cup
Txx pre-sel. product Selects the product associated with
Instant powder 1 the pre-selection. Will only be displayed for
pre-selections 2,5,7. The entry data allowed
here is: Instant powders 1 to 6.
Txx INC Key
Selects the Txx key associated with the
01
product decrease pre-selection function being
programmed. Will only be displayed for pre-
selection 6. The entry data allowed here is:
1 to 12.
Txx prod. timing This is for programming the extra product time
00.0 s
associated with pre-selection. Will only be
displayed for pre-selections 5,7. The entry
data allowed here is: 00.0 to 25.5 s
Txx prod. + timing This is for programming the extra product time
00.0 s
associated with pre-selection. Will only be di-
splayed for pre-selection 7. The entry data
allowed here is: 00.0 to 25.5 s
Enable extra Txx Activates --o ++ product associated with
No
the pre-selection. Will only be displayed for
pre-selection 7. The entry data allowed here
is: No-Yes. (Yes=++)
Note: it is possible to program only one pair of product INC/DEC
pre-selections. Following are a few examples of dose calculations
using the INC/DEC pre-selection function:
1. Instant powder dose=4s, extra instant powder dose=2s, the
instant powder bar is set on 5 of 8 grids: the
new instant
powder dose will be equal to the whole instant powder dose of
4s plus 1⁄4 extr
a instant powder dose, thus making a total of
4.5s.
2. Instant powder dose=4s, extra instant powder dose=2s, the
instant powder bar is set on 3 of 8 grids: the
new instant
powder dose will be equal to only
3⁄4
of the instant powder dose,
for a total of 3s.
3. Generally speaking, the first 4 bar grids each correspond to ¼
of the instant powder dose, whilst the second 4 bar grids
each correspond to 1⁄4 of the extr
a instant powder dose.
No. of bar
grids
Instant
powder dose
Extra instant
powder dose
Dose
dispensed
0
4
2
0
1
4
2
1
2
4
2
2
3
4
2
3
4
4
2
4
5
4
2
4,5
6
4
2
5
7
4
2
5,5
8
4
2
6
Customer number Sets the V.M. customer number
00000
The entry data allowed here is: 0 to
65535.
Language
Sets the V.M. language.
Italian
9 languages are available. The message displayed
in line 2 is no. 169 in the message file.
Currency code
Sets the currency code.
000
The entry data allowed here is: 0 to 999.
Code 1
Sets password for accessing the
00000
complete menu.
The entry data allowed here is: 0 to 99999.
Code 2
Sets password for accessing the
00001
reduced menu.
The entry data allowed here is: 0 to 99999.
Code 3
Sets password for accessing the
00002
sales menu.
The entry data allowed here is: 0 to 99999.
EVA-DTS level
Sets the EVA-DTS data level for download
3
via handheld, via Modules and via PC.
The entry data allowed here is: 1 to 3
Instant grind
Enables the instant grind function.
No
The entry data allowed here is: No or Yes.
Cleaning
Enables wash cycle.
No
The entry data allowed here is: No or Yes.
Wash cycle
Enables periodical wash cycle.
No
The entry data allowed here is: No or Yes.
MENU 3 (TEMPERATURE)
Boiler temp.
Sets the temperature for the cartridge boiler.
90 °C
The first number in line 1 is permanent. The
entry data allowed here is: .70 to 110 °C
MENU 4 (TIMING AND THRESHOLDS)
Grinder timeout
Sets grinder timeout.
13.0 s
The entry data allowed here is: 0.0 to 25.5 s.
Grinder threshold Sets maximum current value
11.0 A
absorbed by the grinder.
The entry data allowed here is: 0.0 to 25.5A.
Group timeout
Sets group timeout.
10.0 s
The entry data allowed here is: 0.0 to 25.5s.
Pump timeout
Sets the maximum activation time timeout
60 s
by the pump.
The entry data allowed here is: 0 to 90 s.
Load timeout
Sets the maximum water load time timeout
90 s
The entry data allowed here is: 5 to 240 s.
Cleaning cycle time Sets cleaning cycle time/cc, based on
10.0 s
flow meter presence.
The entry data allowed here is: 0.0 to 25.5s.
or 0 to 255 cc.
Fan
Sets fan speed for
60
when drink is not being dispensed.
The entry data allowed here is: 60-100%