MENU 5 (PRE-SELECTIONS)

Txx pre-selec 

  Select the Txx key for which the

tions key  

  pre-selection programming is required.    

The entry data allowed here is: 1 to12. 

MENU 5.1 (TXX PRE-SELECTIONS)

Txx pre-sel. option    Entry of the pre-selection option associated

No pre-selection     with the Txx key. The entry data allowed here is: 
 

  1. No pre-selection :No pre-selection

 

  2. Product absent :Product absent

 

  3. Double product 1:Double product 1 

 

  4. Double product 2:Double product 2 

 

  5. INC product :product increase 

 

  6. DEC product :product decrease 

 

  7. Ge. pre-selection :General pre-selection 

 

  8. User jug :General user jug

 

  9. Cup :Cup 

 

  10. No cup :No cup 

Txx pre-sel. product  Selects the product associated with

Instant powder 1    the pre-selection. Will only be displayed for 

pre-selections 2,5,7. The entry data allowed 

here is: Instant powders 1 to 6.

Txx INC Key  

  Selects the Txx key associated with the

01  

  product decrease pre-selection function being 

programmed. Will only be displayed for pre-

selection 6. The entry data allowed here is: 

1 to 12.

Txx prod. timing     This is for programming the extra product time

00.0 s  

  associated  with  pre-selection.  Will  only  be 

displayed for pre-selections 5,7. The entry 

data  allowed here is: 00.0 to 25.5 s

Txx prod. + timing    This is for programming the extra product time

00.0 s  

  associated with pre-selection. Will only be di-

splayed for pre-selection 7. The entry data  

allowed here is: 00.0 to 25.5 s

Enable extra Txx     Activates --o ++ product associated with 

No  

  the pre-selection. Will only be displayed for 

pre-selection 7. The entry data allowed here 

is:   No-Yes. (Yes=++)

Note: it is possible to program only one pair of product INC/DEC 

pre-selections. Following are a few examples of dose calculations 

using the INC/DEC pre-selection function: 
1. Instant powder dose=4s, extra instant powder dose=2s, the 

instant powder bar is set on 5 of 8 grids: the  

new instant 

powder dose will be equal to the whole instant powder dose of 

4s plus 1⁄4 extr

a instant powder   dose, thus making a total of 

4.5s. 

2. Instant powder dose=4s, extra instant powder dose=2s, the 

instant powder bar is set on 3 of 8 grids: the  

new instant 

powder dose will be equal to only 

3⁄4

 of the instant powder dose, 

for a total of 3s. 

3. Generally speaking, the first 4 bar grids each correspond to ¼ 

of the instant powder dose, whilst the second 4   bar  grids 

each correspond to 1⁄4 of the extr

a instant powder dose. 

No. of bar 

grids

Instant 

powder dose

Extra instant 

powder dose

Dose 

dispensed

4,5 

5,5 

Customer number    Sets the V.M. customer number

00000 

  The  entry  data  allowed  here  is:  0  to 

65535.

Language 

  Sets the V.M. language.

Italian 

  9 languages are available. The message displayed 

in line 2 is no. 169 in the message file.

Currency code 

  Sets the currency code.

000 

  The entry data allowed here is: 0 to 999.

Code 1 

  Sets password for accessing the

00000 

  complete menu. 

 

  The entry data allowed here is: 0 to 99999.

Code 2 

  Sets password for accessing the

00001 

  reduced menu. 

 

  The entry data allowed here is: 0 to 99999.

Code 3 

  Sets password for accessing the

00002  

  sales menu. 

 

  The entry data allowed here is: 0 to 99999.

EVA-DTS level 

  Sets the EVA-DTS data level for download 

  via handheld, via Modules and via PC.

 

  The entry data allowed here is:  1 to 3

Instant grind 

  Enables the instant grind function.

No 

  The entry data allowed here is: No or Yes.

Cleaning  

  Enables wash cycle.

No 

  The entry data allowed here is: No or Yes.

Wash cycle  

  Enables periodical wash cycle.

No 

  The entry data allowed here is: No or Yes.

MENU 3 (TEMPERATURE)

Boiler temp.  

  Sets the temperature for the cartridge boiler.

90 °C 

  The first number in line 1 is permanent. The 

entry data allowed here is: .70 to 110 °C 

MENU 4 (TIMING AND THRESHOLDS)

Grinder timeout 

  Sets grinder timeout. 

13.0 s  

  The entry data allowed here is: 0.0 to 25.5 s.

Grinder threshold      Sets maximum current value  

11.0 A 

  absorbed by the grinder. 

 

  The entry data allowed here is: 0.0 to 25.5A.

Group timeout  

  Sets group timeout. 

10.0 s  

  The entry data allowed here is: 0.0 to 25.5s.

Pump timeout  

  Sets the maximum activation time timeout

60 s 

  by the pump. 

 

  The entry data allowed here is: 0 to 90 s.

Load timeout  

  Sets the maximum water load time timeout 

90 s  

  The entry data allowed here is: 5 to 240 s.

Cleaning cycle time   Sets cleaning cycle time/cc, based on

10.0 s 

  flow meter presence. 

  

  The entry data allowed here is: 0.0 to 25.5s.

 

  or 0 to 255 cc.

Fan  

  Sets fan speed for

60 

  when drink is not being dispensed. 

 

  The entry data allowed here is: 60-100% 

Содержание BVM 901 LEISA

Страница 1: ...BVM 901 LEIsa CERT N 9191 BNVN UNI EN ISO 14001 2004 CERT N 9105 BNVD UNI EN ISO 9001 2000 USE AND MAINTENANCE MANUAL...

Страница 2: ......

Страница 3: ...intended to come into contact with foodstuffs The tests have been made in accordance with the Harmonized European Standards 1 LOW VOLTAGE Electrical safety LV EN 60335 1 2002 A1 A11 Safety of Househol...

Страница 4: ...ntribuisce ad evitare possibili effetti negativi sull ambiente e sulla salute e favorisce il riciclo dei materiali di cui composta l apparecchiatura Lo smaltimento abusivo del prodotto da parte dell u...

Страница 5: ...ined as the person responsible for the installation of the automatic distri butor the starting up operations and the function settings Each regulation operation is the exclusive responsibility of the...

Страница 6: ...2 SPANNERS fork type n 7 n 8 n 10 n 12 n 14 SCREWDRIVERS Small size Medium size Large size Normal cross Small cross Medium cross Large cross Of Teflon small size for Trimmer regula tion RATCHET SPANNE...

Страница 7: ...manual is an integral part of the equipment and as such must always remain inside of the same so as to allow further consultations on the part of the various operators until the dismantlement and or...

Страница 8: ...or belongings in consequence to Incorrect installation Inappropriate electrical and or water connection Inadequate cleaning and maintenance Not authorized modifications Improper use of the distributor...

Страница 9: ...kW to 2 5 kW Nominal current 7 42 A AVERAGE CONSUMPTIONS Water supply connection 3 4 gas Electrical supply connec Schuko plug WATER SUPPLY from main supply with pressure between 0 5 and 6 5 bar BOILE...

Страница 10: ...ee group and grinder 2 Container units for soluble drinks 3 Coffee bean container 4 Coin mechanism 5 Switching 6 Cup holder 7 Instant boiler 8 Dispensing chamber 9 Keyboard 10 Master board 11 Coffee g...

Страница 11: ...or the dispensing of drinks pre pared mixing food substances with water by infusion as far as concerns coffee For this purpose use products declared as suitable by the manu facturer for automatic dist...

Страница 12: ...e user shall therefore independently see to obtaining them via the appropriate dispenser available in the vicinity of the vending machine and shall ensure that they are correctly positioned in the dis...

Страница 13: ...pump that dispenses the quantity of programmed water is activated and is controlled by an appropriate electronic device volumetric counter The instant product geared motor activates the helicoidal scr...

Страница 14: ...eared motor brings it into the dispensing position and simultaneously compresses the ground coffee Fig 3 12 the pump that dispenses the quantity of programmed water and that is controlled by a specifi...

Страница 15: ...rene packaging Fig 4 2 The automatic distributor will be delivered packed assuring both a mechanical protection and protection against damages from the external environment On the package labels are a...

Страница 16: ...butor and remove the adhesive tape from the components listed here below coin mechanism cover keyboard cards product containers The packing material must not be left accessible to others as it is a po...

Страница 17: ...e or belongings in consequence to Incorrect installation Inappropriate electrical and or water connection Inadequate cleaning and maintenance Not authorized modifications Improper use of the distribut...

Страница 18: ...e from the water mains should it be found to be necessary Fig 6 3 before making water connections make some water flow out of the tap so as to eliminate possible traces of impurities and dirt Fig 6 4...

Страница 19: ...upply cable of H05VV F 3x1 mm with SCHUKO plug Fig 6 8 The sockets that are not compatible with that of the machine must be replaced Fig 6 9 The use of extension adapters and or multiple plugs is forb...

Страница 20: ...tributor is started up the airbreak is filled with wa ter When the floater is in the upper position the machine will start loading water automatically and this will go on until 300cc of water are coun...

Страница 21: ...nds carefully prepare an anti bacterial cleaning solution with a chlorine base products that can be purchased in pharmacies following the concentrations given on the product instruction labels Before...

Страница 22: ...18 the parts must soak in the solution for the time indicated on the solutions instruction label Recover all the parts rinse them abundantly dry them perfectly and proceed with the re assembly in the...

Страница 23: ...S so as to ve rify setting of the parameters that must be coherent with the system used 6 7 Product container loading with machine off 6 7 1 Loading containers Filling is possible keeping the containe...

Страница 24: ...d 13 to 24 according to the following table Key number BVM901 DP1 Key 1 DP1 Key 2 DP1 Key 3 Selection 13 DP1 Key 4 Selection 14 DP1 Key 5 Selection 15 DP1 Key 6 Selection 16 DP1 Key 7 Selection 17 DP1...

Страница 25: ...s pw will access all the menu items that are worth programming and as actually needed Programmable parameter 2 Limited menu programming password this pw will access only the items enabled via the redu...

Страница 26: ...only 3 4 of the instant powder dose for a total of 3s 3 Generally speaking the first 4 bar grids each correspond to of the instant powder dose whilst the second 4 bar grids each correspond to 1 4 of...

Страница 27: ...presso sugar 00 0 s function With P going from P1 to P24 The entry data allowed here is 0 0 to 25 5 s Ev Nr P Sets the electro valve number 0 With P going from P1 to P24 stands for the order of the el...

Страница 28: ...depends on the decimal point MENU 10 3 BANKNOTES LINE Banknote xx Sets the value to be associated with 000 00 banknote xx Where xx 1 to 16 The entry data allowed here is 0 to 65535 and display depend...

Страница 29: ...data allowed 0 65535 Sect A decount Vega sector xx decounter value 00000 with xx 1 max number of sectors Entry data allowed 0 65535 MENU 17 3 RESERVE Enab Powd Res Enables instant powder decounter res...

Страница 30: ...switch off time slot functions based on activation of the ma chine s switch off parameter that can be set via the windows program If the start value is bigger or equal to the end value the time slot i...

Страница 31: ...n The following message comes up on display in line 1 Test run complete ONLY WATER TEST This function allows the operator to run test selections of the possible drinks available without the powders be...

Страница 32: ...t s On application of the HACCP certain hygienic regulations are laid down for company self checking procedures concerning Cleaning of the premises Product transportation Machinery maintenance Waste d...

Страница 33: ...can be removed from its housing to make the task easier Fig 9 6 empty the waste liquids bin clean it and or substitute it Fig 9 7 substitute the coffee spent grounds container coffee in beans versions...

Страница 34: ...dge of the equipment is necessary Monthly effect the debacterisation of all the parts in contact with food substances using chlorine based solutions following the operations already described under ch...

Страница 35: ...cone grease for alimentary use Fig 9 12 lower filter piston 1 connecting bar 2 piston guide 3 Every 10000 vends we advise to substitute the gaskets and the filters gaskets Loosen the screw Fig 9 13 wa...

Страница 36: ...must be carried out in order to assess the efficiency of the regulation the finer the granules the greater the time required for product delivery 9 3 2 Regulation of the instant solenoid water deliver...

Страница 37: ...divided by the payment system s basic currency amounts to more than 250 The alarm is auto resetting and it will therefore disappear as soon as the price that is higher than the test parameter is repro...

Страница 38: ...null The alarm warning is auto resetting therefore it will reset itself immediately as soon as the decounter value is programmed Electro valves Electro valve decounter not blocking warning Occurs if t...

Страница 39: ...blematiche utilizzare il presente modulo per segnalare alla Bianchi la problematica e richiedere pezzi di ricambio in garanzia Si fa notare che la spedizione di questo modulo compilato la condizione p...

Страница 40: ......

Страница 41: ...ole Motori Elettromagneti Indirizzo e mail N ro Fax per conferma attivazione garanzia DA INVIARE FAX 39 035 883304 o e mail customercare bianchivending com Matricola N tel Cliente SCHEDA RICHIESTA RIC...

Страница 42: ......

Страница 43: ......

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ......

Страница 49: ......

Страница 50: ...Cod 11116621 Ediz 10 2009...

Отзывы: