13
Message Memory:
5.625 MB
Network Audio:
20-bits, 48kHz, 5-1/3 ms (fixed)
Network Connections:
RJ45 with shielded Ethernet cable
(CAT5, CAT5e, CAT6 or CAT 7)
Analog Inputs:
(VA-2060e and VA-4030e) Per Channel
Nominal Input Range:
-66dBu to 0dBu
Maximum Input Level: +24dBu
Equivalent Input Noise:
(max Gain) >-125dbu
Dynamic Range: >94dB
Input Impedance: 8k
Ω
Phantom Power:
+48V DC
Frequency Response:
40Hz-20kHz +/- 2dB
Signal to Noise Ratio:
>88dB, unweighted
THD + Noise:
<0.5% 50Hz-100Hz
<0.3% 100Hz-10kHz
Rated Output Power:
VA-2060:
2x 60W RMS, total 120W
VA-2060e:
2x 60W RMS, total 120W
VA-4030:
4x 30W RMS, total 120W
VA-4030e:
4x 30W RMS, total 120W
Supported Loads:
Low Impedance:
4
Ω
, 8
Ω
Constant Voltage:
25V, 70V or 100V
Output Configuration:
Transformer Coupled (ground free)
Output DC Offset:
<100mV
PAR Relays
Form:
Single Form C contact
Max Operating Voltage:
125V AC, 60V DC
Max Operating Current:
100mA AC, 1A DC
Power:
AC (all amplifiers):
100V-240V AC, 50H 60 Hz
DC (VA-2060e and VA-4030e):
Nominal 24V DC
Continuous power rating
60 Watts
Peak Power rating
150 Watts
DC Range:
18V-30V; <100mV Ripple
Overall Dimensions:
Height:
3.25 in (82.5mm)
Width:
19 in (483mm)
Depth:
14.2 in (360mm)
Weight:
VA-2060:
24.7lbs (11.2kg)
VA-2060e:
24.9lbs (11.3kg)
VA- 4030:
26.0lbs (11.8kg)
VA- 4030e:
26.2lbs (11.9kg)
Compliance:
FCC Part 15B
EN 54-16 certified
UL 60065 and C-UL listed
CCC pending
C-Tick
RoHS Directive
2002/95/EC
EN 60849, AS 60849 verified
Environment
Ambient Operating Temperature Range:
18-108 degrees F (-8 – 42° C)
Ambient Intake:
Humidity:
0 – 100% non-condensing
Altitude:
0 – 10,000 Feet MSL
VOCIA AMPLIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e SPECIFICATIONS