background image

   

A:

 9300 Gemini Drive, Beaverton, OR 97008          

  

T:

 +1 877.242.6796 

      

 

W:

 www.biamp.com

Network Box Front Panel

Front Panel and Connectors

1.  Mic

Two RJ-45 ports allow for connecting one TTM-X microphone and an additional 

TTM-XEX expander microphone. If using only one microphone, it must be 

connected to the Mic 1 port. Use of the second RJ-45 port is optional.

2.  Power/System Status Indicator                                                                                             

A multi-color LED provides information about the status of the device.

Status

LED Indicator

No Power

Off

Boot/Self-test

Red Solid

Ready to receive configuration or updating firmware

Yellow Solid

Configured and ready to participate in the system

Green Solid

Unit is in Locate mode (triggered by software)

Green Flashing

Unit has Major Alarm condition

Red Flashing

Unit has Major Minor condition

Yellow Flashing

Unit has both a Major and Minor Alarm condition

Red/Yellow Flashing

3.  AVB/Control                                                                                          

Facilitates connection to the Tesira AVB network for audio transmission and 

control. This RJ-45 port may either be connected directly to the Tesira AVB port 

(via a PoE+ injector) for a single device system, or via a PoE+ network switch or 

TesiraConnect device in a multi-device AVB system.

4.   Cable Attachment Point

Secures excess cable.

5.

   

Mute Button

Mutes the microphone when the button is pressed. If “Mute mics as a group” 

is enabled within the Tesira software, pressing the Mute button will mute all 

microphones attached to the same network box.   

                                                                               

6.

   

LED Indicator

Three multi-color LEDs provide information about the status of the microphone. 

Default LED indication is shown in the table below. Default LED behavior may 

be changed through configuration of the system.

Status

LED Indicator

No Power

Off

Configured and operating normally

Green Solid

Microphone is Muted

Red Solid

Unit has Major Alarm condition

Red Flashing

Table Microphone

Figure 1 Parlé TTM-X Network Box

Figure 2 Parlé TTM-X Microphone