A:
9300 Gemini Drive, Beaverton, OR 97008
T:
+1 877.242.6796
W:
www.biamp.com
Network Box Front Panel
Front Panel and Connectors
1. Mic
Two RJ-45 ports allow for connecting one TTM-X microphone and an additional
TTM-XEX expander microphone. If using only one microphone, it must be
connected to the Mic 1 port. Use of the second RJ-45 port is optional.
2. Power/System Status Indicator
A multi-color LED provides information about the status of the device.
Status
LED Indicator
No Power
Off
Boot/Self-test
Red Solid
Ready to receive configuration or updating firmware
Yellow Solid
Configured and ready to participate in the system
Green Solid
Unit is in Locate mode (triggered by software)
Green Flashing
Unit has Major Alarm condition
Red Flashing
Unit has Major Minor condition
Yellow Flashing
Unit has both a Major and Minor Alarm condition
Red/Yellow Flashing
3. AVB/Control
Facilitates connection to the Tesira AVB network for audio transmission and
control. This RJ-45 port may either be connected directly to the Tesira AVB port
(via a PoE+ injector) for a single device system, or via a PoE+ network switch or
TesiraConnect device in a multi-device AVB system.
4. Cable Attachment Point
Secures excess cable.
5.
Mute Button
Mutes the microphone when the button is pressed. If “Mute mics as a group”
is enabled within the Tesira software, pressing the Mute button will mute all
microphones attached to the same network box.
6.
LED Indicator
Three multi-color LEDs provide information about the status of the microphone.
Default LED indication is shown in the table below. Default LED behavior may
be changed through configuration of the system.
Status
LED Indicator
No Power
Off
Configured and operating normally
Green Solid
Microphone is Muted
Red Solid
Unit has Major Alarm condition
Red Flashing
Table Microphone
Figure 1 Parlé TTM-X Network Box
Figure 2 Parlé TTM-X Microphone