background image

13

AudiaFUSION wARRANTY

BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF 
THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL

1.  BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and 

workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the 

 

terms and conditions set forth below.

2  If you notify BIAMP during the warranty period that a BIAMP Systems product fails to comply with the warranty, BIAMP Systems 

will repair or replace, at BIAMP Systems’ option, the nonconforming product.  As a condition to receiving the benefits of this warranty, 

you must provide BIAMP Systems with documentation that establishes that you were the original purchaser of the products. Such 

evidence may consist of your sales receipt from an authorized BIAMP Systems dealer. Transportation and insurance charges to 

and from the BIAMP Systems factory for warranty service shall be your responsibility.

3.  This warranty will be VOID if the serial number has been removed or defaced; or if the product has been altered, subjected to 

 

damage, abuse or rental usage, repaired by any person not authorized by BIAMP Systems to make repairs; or installed in any 

manner that does not comply with BIAMP Systems’ recommendations.

4.  Electro-mechanical fans, electrolytic capacitors, gooseneck microphones, cords connecting handheld microphones, hard-drives, 

displays, and normal wear and tear of items such as paint, knobs, handles, keypads and covers are not covered under this warranty. 
All server-based devices are warranted for 3 years only. 

5.  This warranty is in lieu of all other warranties, expressed or implied. Biamp Systems disclaims all other warranties, expressed 

or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose.

6.  The remedies set forth herein shall be the purchaser’s sole and exclusive remedies with respect to any defective product. 

7.  No agent, employee, distributor or dealer of BIAMP

 Systems is authorized to modify this warranty or to make additional warranties on 

behalf of BIAMP Systems. Statements, representations or warranties made by any dealer do not constitute warranties by BIAMP 
Systems. BIAMP Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or 
other person.

8.  No action for breach of this warranty may be commenced more than one year after the expiration of this warranty.

9.  Biamp systems shall not be liable for special, indirect, incidental, or consequential damages, including lost profits or loss of use 

arising out of the purchase, sale, or use of the products, even if BIAMP Systems was advised of the possibility of such damages.

Содержание AUDIAFUSION

Страница 1: ...Audia AudiaFUSION Manual Biamp Systems 9300 S W Gemini Drive Beaverton OR 97008 USA 1 503 641 7287 www biamp com ...

Страница 2: ...IMPORTANT SAFETY INSTRUCTIONS ...

Страница 3: ...s Indicators 5 rear panel 6 9 Serial Control Port 6 Power Entrance 6 NM 1 6 Logic I O 6 Ethernet 6 CobraNet 6 AM 600 7 Output 7 Amplifier to Amplifier Failover 8 Channel to Channel Failover 9 AudiaFUSION AM 600 CARD specifications 10 115 VAC Current Draw and Heat Output 11 Block diagram 12 warranty 13 ...

Страница 4: ... processing resources are allocated as needed making the whole system more efficient alarm activity signal 1 signal 2 status ais power FEATURES Modular based design Amplification modules have software configurable power levels load options 8 amplification modules per frame with 100W to 600 Watts per module maximum of 2400W per chassis 70 V or 100 V with direct drive capability or low impedance 4 o...

Страница 5: ... occurred Two types of channel faults can be reported depending on the severity of the problem Amber indicates a Warning which means that some aspect of the AM 600 amplifier module is not performing within normal specification Audio may still be passing but if the condition causing the Warning is not corrected channel failure may occur Red indicates an Alarm which means that some aspect of the AM ...

Страница 6: ...ay no longer be passing through the device Use the Audia software to determine the specific type of chassis warning or alarm that has occurred Activity is a tri color LED that illuminates to show the configuration status of the AudiaFUSION unit If the LED is dark there is no configuration in the unit A green LED indicates that the unit is configured and an amber LED indicates that the unit is conf...

Страница 7: ...or PC computers with Windows XP Professional Vista operating system required The PC computer must have a network card installed that supports 10 100Base T Ethernet A 10 100Base T Ethernet switch not repeater hub is required when networking multiple units AudiaFUSION uses standard CAT5 CAT5e CAT6 or CAT7 cabling which has a specified maximum length of 100 meters Additional Ethernet switches and or ...

Страница 8: ...or as stray strands can short to the adjacent terminal or chassis Do not leave excessive bare wire outside the terminals as this can lead to shorts Left LED Right LED Description None None No data connectivity Green None Link established Green Flashing amber Link established and CobraNet activity detected the unit is acting as a CobraNet performer Flashing green Flashing amber Link established and...

Страница 9: ...he primary amplifier to logic 3 of the redundant amplifier connect logic 3 of the primary amplifier to logic 4 of the redundant amplifier Leave logic 1 and 2 disconnected The redundant amplifier can be wired in parallel to the existing speaker line or connected to a redundant speaker line see figure below Relays isolate the output terminals on the secondary AudiaFUSION unit Relays are normally ope...

Страница 10: ...e redundant channel can be wired in parallel to the existing speaker line shown above or connected to a redundant speaker line The primary amplifier module will resume control after the fault condition is cleared and the unit is re powered OUTPUT Class 2 Wiring AM 600 OUTPUT Class 2 Wiring AM 600 1 2 OUTPUT Class 2 Wiring AM 600 OUTPUT Class 2 Wiring AM 600 1 2 Primary Redundant Redundant Wiring P...

Страница 11: ... 101 dB 102 dB 103 dB 102 dB 102 dB 103 dB 102 dB 103 dB 104 dB Intermodulation distortion SMPTE 0 2 Inter channelIsolation 75 dB 20 Hz 20 kHz full power out DC offset 10mV 1 In chassis with fans running normally and unrestricted intake and exhaust AudiaFUSION SPECIFICATIONS Inputs 20 bits 48 kHz supported CobraNet latency 5 1 3 2 2 3 or 1 1 3 ms software configurable Overall Dimensions Height Wid...

Страница 12: ...AMPLIFIER CARD CLASS D AMPLIFIER DSP DSP Display CobraNet uC CobraNet Audio Ethernet Control 10 100 ETHERNET FAN CONTROL FAN 1 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 TEMPERATURE IMPEDANCE MONITORING DC DETECTION I V FAN 2 RS 232 LOGIC Serial I O Logic I O ...

Страница 13: ... cards 0 0 3 106 NA NA NA NA NA NA 100 1 0 4 143 0 7 227 0 9 244 1 6 406 200 1 0 4 143 0 8 239 1 3 271 2 7 491 300 1 0 4 143 1 0 251 1 6 300 3 8 590 400 1 0 4 143 1 1 263 2 0 333 4 9 668 500 1 0 4 143 1 3 278 2 4 356 6 1 788 600 1 0 4 143 1 4 297 2 8 413 7 3 910 700 2 0 5 177 1 8 418 3 4 551 8 9 1211 800 2 0 5 177 2 0 430 3 8 577 10 0 1296 900 2 0 5 177 2 1 442 4 2 607 11 1 1395 1000 2 0 5 177 2 2...

Страница 14: ...any manner that does not comply with BIAMP Systems recommendations 4 Electro mechanical fans electrolytic capacitors gooseneck microphones cords connecting handheld microphones hard drives displays and normal wear and tear of items such as paint knobs handles keypads and covers are not covered under this warranty All server based devices are warranted for 3 years only 5 This warranty is in lieu of...

Страница 15: ...t 8 VoIP 2 Voltage Control Box Product Description Audio Digital Signal Processors and Control Accessories Applicable EC Directives Applicable Harmonized Standards LVD Directive 2006 95 EC Safety EN 60065 2002 EMC Directive 2004 108 EC Emissions EN 55103 1 1996 Environment E2 Immunity EN 55103 2 1996 R TTE Directive 1999 5 EC Terminal Equipment AudiaFLEX with TI 2 only Special Considerations for P...

Страница 16: ...15 15 compliance ...

Страница 17: ...16 IMPORTANT SAFETY INSTRUCTIONS ...

Страница 18: ...17 IMPORTANT SAFETY INSTRUCTIONS ...

Страница 19: ...18 IMPORTANT SAFETY INSTRUCTIONS ...

Отзывы: