BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
7
4
STORAGE
The device has to be stored in a clean and dry room. Protect the device from rain and direct sunshine.
After heating completion, leave the device switched on for 10 more minutes - it will be cooled down by
fans until it is cold, then it deactivates the fans. After that, turn it off using the master switch and
disconnect it from the power line.
If you disconnect the device immediately, leave it and all the working coils to cool down for at least 15
minutes.
5
ACTIVATING THE DEVICE
5.1
Unpacking and first start
1.
Unpack the device and any accessories supplied and check that they are in good order and the
device and the accessories are not damaged. If you find any defects, do not continue!
2.
Leave the device to acclimatise for 15 minutes.
3.
Remove the sealing ring located under the coolant tank filling hole lid tab. Pull to remove the lid
tab and take out the sealing O-ring. Then push the tab, including the foam gasket, back into the
tank lid. Keep the O-ring for potential future use if sending the machine via a parcel service.1.
4.
If the focusing head is not attached to the grip by default, screw it on.
5.
Fill the device with the coolant supplied with the device via the filling hole.
6.
Connect the device to a 230V socket and turn it on using the switch at the back of the device.
7.
The cooling circuit venting is activated automatically, and the letters “FIL” flash on the display
during this. The coolant level decreases noticeably during the filling.
8.
After completion of the venting, turn the device off and add the coolant so that the coolant level
is at the upper edge of the gauge at the back of the device (about 1 cm below the top of the
tank.
9.
Turn the device and let the venting proceed. If the level does not sink, the device is filled and
vented correctly. Repeat the procedure as needed.
5.2
Coolant refilling
Check and refill the coolant before each device starting. Use the original coolant only! DO NOT USE
WATER!
The device has integrated coolant level inspection. In case the coolant runs out, the device stops
heating and displays an error message.
6
REPLACEABLE HEATING INDUCTOR EXTENDERS
This induction heater device comes with a basic focusing heating inductor.
Correct and safe functioning of the device requires the use of only original heating inductors,
extenders, adaptors and other accessories in accordance with their respective instructions for use.
The lifetime of each type of heating inductor and accessory is shown in its instructions for use along
with inspection and maintenance frequencies.