Menu System

= Quick Menu

X 2 Rapidly = Traditional Menu

To enter the traditional Menu press the OK button twice rapidly, Halt > OK 
> Follow user guide OK > Para >Logic>Radio>Default 

Содержание Rigel 6 QRG

Страница 1: ...nings in the main instruction document first Always apply good safe state of the art engineering and electrical installation principles Safety of the completed installation is the ultimate responsibility of the installer This product is not suitable for DIY use and should only be installed and maintained by a trained skilled professional installer ...

Страница 2: ...individual transmitters Ø Magnetic lock powered constantly during closing cycle Ø U Link Ø 6 safe inputs Safe 1 2 8K2 Ø Reset able low voltage fuse Ø Auto set for both Hydraulic Electro mechanical motors Ø Obstacle Detection electro mechanical motors ONLY Ø Gate open close buttons on control board Ø Error messages on cover lid and on control panel 30 errors ...

Страница 3: ...Terminal Layout ...

Страница 4: ...Rigel 5 to Rigel 6 terminal numbers ...

Страница 5: ...Motor Connections Old Rigel 5 New Rigel 6 Motor 1 10 11 12 opens first followed by Motor 2 14 15 16 Motor 2 closes first followed by Motor 1 Capacitor is connected across motor winding M1 10 12 M2 14 16 ...

Страница 6: ...0 21 11 12 14 15 16 10 22 23 24 25 26 27 28 29 60 61 62 63 64 65 73 74 75 76 77 78 78 M2 M1 Capacitor Capacitor 8K2 resistive 70 72 or 70 74 Logic 8 51 50 4 1 2 51 52 Desme 75 76 SAFE 3 004 Photo cells active closing only Ic Inputs 1 2 3 4 Mag Lock or CISA ...

Страница 7: ...Menu System Quick Menu X 2 Rapidly Traditional Menu To enter the traditional Menu press the OK button twice rapidly Halt OK Follow user guide OK Para Logic Radio Default ...

Страница 8: ...Quick Menu Layout This will provide a working system ...

Страница 9: ...d mandatory for hydraulics except Lux FC Manual release and set limit switch positions Igea only Connect up the motor supply cables to the Blue connectors 10 11 12 14 15 16 Do NOT connect any accessories at this stage and leave all factory links fitted Position gates in the closed position Sub Lux P Series Kustos Igea Eli 250 leave in the factory set position Navigate to the Autoset menu and launc...

Страница 10: ...en the closed position is reached press the OK button With showing press the OK button 3 2 1 motor 1 will open followed by motor 2 from the open position motor 2 will close first followed by motor 1 upon completion OK will be displayed If the motors try to close at the launch of the Autoset then the motor cables must be swapped 10 12 14 16 When a gate system is powered for the first time or after ...

Страница 11: ...Time Clock Setting Clock for the day of the week Day of install i e Tuesday ...

Страница 12: ... ie 08 00 First OFF ie10 20 Second ON ie 15 00 Second OFF ie 16 10 Programming in 10 min blocks 1 10 past the hour 2 20 past 3 30 past 4 40 past 5 50 past Example 1st ON 08 30 08 3 1st OFF 09 50 09 5 Set Chrono Time Bands in Logic to 1 for timer 2 for ped timer ...

Страница 13: ...Radio Individual transmitters can be removed from any channel The location number within the radio channel must be known to carry out this function ...

Страница 14: ...button on a Mitto into the 2nd radio channel Program Ic1 5 60 61 Aux Out 2 14 24 25 2ch 8 Wire between 24 61 25 60 How to open the Pedestrian leaf on the Third button on a Mitto 2 4 Code the Third button on a Mitto into the 3rd radio channel Program Ic2 4 60 62 Aux Out 3 0 3ch 4 Wire link between 26 62 27 60 ...

Страница 15: ...Obstacle Sensitivity ...