KUSTOS ULTRA BT 

Maximum Power

Maximum Cycle

Motor 1 opens first.

S3 13s-1-13s-1 x30

40 W

pause

90min. 

 

Thalia control board

JP

5

JP7

Y

#

F2 3,15 AT

F1 1.25 

AT

(220-230V)

F1  2.5 

AT (120

V

)

ANT

220-230V ~

*

S2

S1

S3

L N

10 11

L N

M1

220-230V ~

*

14 15 20 21 26 27 40 41 42 43 44 45 50 51 52

60 61 62

70 71 72 73 74 75

+

M2

24V

AUX 3 

(MAX 24V 1A)

SN 1

SN 2

24V -

24V +

24 VSafe+

COM

IC 1

IC 2

COM

SAFE 1

STOP

FAULT 1

SAFE 2

FAULT 2

-

+ -

NO

NO

NC

NC

NC

JP21

Antenn

e

Optional

board connector,

Safety devices

Commands

AUX

Power supply

Motor 

limit switch 

inputs

Accessories 

power 

supply

40 41 42 43 44 45

SW 1 

10 11

M1

14 15

+

M2

-

+

-

SW 2 

 

 

 

1

2

3

SW 1

M1 +

M1-

 

 

 

 

 

 

 

 

 

1

2

3

SW 2

M2 +

M2-

THALIA

1

Simplified menu: basic regulations

Click OK

Upward/Downward

x1

Motor at stroke centre and in gear:

- apply power

- 1x OK: language appears. 3x - (ENG) + click OK
- select “type” of motor. x - (Kustos) + click OK
- select number of motors (n. mot.). 2x - + click OK
- select direction (direction of opening). Select (int. or ext.) + click OK
- select preset. (Ar: auto closure or Sr: semi-auto closure). click OK
- start autoset with panels at half-travel; they close. 
If this is not a closing operation, then press +- simultaneously.
Reconnect the motors in the right direction (motor 1 switch 10&11; motor 2 switch 14&15)
When autoset is finished, the display show OK.

As an option, you can go even further... 

4

How to perform an open/close test by using the remote control.

3

How to programme the remote control 

- Access the radio menu

- Select the channel you want (“add start” total opening or “add2ch” for the 2nd channel), then press OK.

Screen display

Screen display

Screen display

Screen display

hidden button

Ok + key no

release

desidered button

Press the 2 top keys 

simultaneously (hidden 

key), until the screen 

displays...

Select the key to be 

programmed, with a 

single push

1 - I wish to de-activate the photocells while opening:

Access the 

Logic

 menu, scroll down to screen SAFE 1, 

go to 4.

2 - I wish to access automatic closing:

Access the 

logic

 menu, scroll down to the TCA screen, 

go to 1.

3 - I wish to adjust the automatic closing time: 

Access the 

Param

 menu, click OK, and scroll down to 

the TCA screen, enter the value and click OK.

4- I wish to activate pedestrian opening:

Access the 

Logic

 menu; scroll down to screen AUX 3, go 

to 1.(then continue programming the 2nd key on your 

remote control).

language

Dir

ITA

fra

deu

eng

esp

int

EXT

type

eli

2

n. mot.

1

.....

phobos BT A

phobos N

AR

preset

sr

ac

sc

ind

24V

2

1

TX1

2

1

RX1

4

5

3

50 51 52

70 72 73

SAFE1= 1 , 3 , 5

24V

2

1

TX1

2

1

RX1

4

5

3

50 51

70 72

SAFE1= 0, 2,  4

Wire the THEA photocells.

2b

2a

Wire the DESME photocells.

or