INSTALLATION MANUAL
TABLE B: LOGIC MENU (
logic
)
Logic
Default Definition
Cross
out
setting
used
Description
TCA
ON
Automatic
Closing Time
ON
Switches automatic closing on.
OFF
Switches automatic closing off.
Ibl open
ON
Block Pulses
ON
The start pulse has no effect during opening.
OFF
The start pulse has effect during opening or closing.
ibl TCA
OFF
Impulse lock TCA
ON
The Start impulse has no effect during the TCA dwell period.
OFF
The Start impulse becomes effective during the TCA dwell period.
2 step
OFF
2 step
ON
Enables the 2-step logic (prevails over
the “3-step logic”).
Response to the START impulse
Barrier
2 steps
3 steps
4 steps
closed
opens
opens
opens
on closing
stop
open
closes
closes
closes
on opening
stop + TCA stop + TCA
after stop
opens
opens
opens
OFF
Disables the 2-step logic, activating the
4-step logic if the “3-step logic” is OFF.
3 step
ON
3 step
ON
Enables the 3-step logic (if the “2-step
logic” is OFF).
OFF
Disables the 3-s6tep logic, activating the
4-step logic if the “2-step logic” is OFF.
preal
OFF
Pre-alarm
ON
The flashing light comes on approx. 3 seconds before the motors start.
OFF
The flashing light comes on at the same time as the motors start.
hold to
Run
OFF
Deadman
ON
Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE
control keys are kept pressed. The radio transmitter cannot be used.
OFF
Normal impulse operation.
Photoc.open
ON
Photocells
during opening
ON
When beam is broken, operation of the photocell is switched off during opening. During closing,
movement is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and closing. When beam is
broken during closing, movement is reversed only once the photocell is cleared.
fast cls
OFF
Rapid closing
ON
Closes barrier after photocell disengagement, before waiting for the end of the TCA (automatic
closing time) set.
OFF
Command not entered.
test phot
OFF
Photocell test
ON
Switches photocell testing on
OFF
Switches photocell testing off
If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not
equipped with supplementary test contacts.
ster
OFF
Master/slave
ON
Control panel is set up as the Master unit in a centralized serial connection system.
OFF
Control panel is set up as a Slave unit in a centralized serial connection system.
fixed code
OFF
Fixed code
ON
Receiver is configured for operation in fixed-code mode.
OFF
Receiver is configured for operation in rolling-code mode.
radio prog
ON
Remote control
programming
ON
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has
already been memorized in standard mode via the radio menu.
2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be
memorized.
The receiver exits programming mode after 10 secs.: you can use this time to enter other new
transmitters. This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
OFF
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
alar sca
ON
SCA Alarm
ON
The SCA contact (terminals 21-22) behaves as follows:
- with barrier open and on opening: contact closed (warning light on)
- with barrier closed:contact open: (warning light off)
- on closing: intermittent contact (blinking)
OFF
The SCA contact closes according to the modes set by the Alarm Time parameter.
change ot.
OFF
Reversing motion
ON
Change this parameter if the opening direction needs to be changed
OFF
Standard operating mode.
open-ti er
(special dip 2*)
OFF
TIMER su OPEN
ON
Input between terminals 15-27 works as TIMER.
OFF
Input between terminals 15-27 works as OPEN.
*=Refer for universal handheld programmer.
28
- GIOTTO 30-50 S BT / GIOTTO 30-50 BT
D811768 00100_03