44 - Espas 20I
D812913 10598_02
Operator Cards allows enabling up to 400 cards using the Espas Conf. software. 400 num-
bered positions are indicated, to which the 125KHx cards can be associated; each position
has a specific function:
Position Function
1,2,3,4
Normal
5,6,7,8
Open
9,10,11,12
Closed
13,14,15,16
Loop (automatic)
17...400
Single pass (Free pass)
INSTRUCTIONS
:
- Enter the menu and scroll with LEFT and RIGHT until Operator Card is displayed
- Scroll through the positions with UP and DOWN
- When the desired position is reached , press PUSH: the value saved in that position starts
flashing:
submit the card you wish to enable to the reader on the front.
- Press PUSH to confirm
01.00000000 norm
4
AVVICINARE CARD
AL LETTORE FRONTALE
CARD PROGRAMMATA
CON FUNZIONE OPEN
OPERATOR CARDS
05.00000000 open
05.00000000 open
05.10456985 open
PULSANTE DI RESET
Grace time is a time value expressed in minutes, that determines how long a customer can
take to get out of the car park from the moment the barcode is printed after payment.
ATTENTION! Grace Time must be set on all devices.
INSTRUCTIONS
:
- Enter the menu and scroll with LEFT and RIGHT until GRACE TIME is displayed
- Press PUSH and modify the value with UP or DOWN
- Press PUSH to confirm
GRACE TIME = 000
GRACE TIME = 010
GRACE TIME = 008
10
2
GRACE TIME = 8
14.1 - GRACE TIME SETTING
14.2 - OPERATOR CARD CONFIGURATION
CARD PROGRAMMED
WITH OPEN FUNCTION
RESET BUTTON
PLACE THE CARD NEAR
THE FRONT READER
Содержание Espas 20I
Страница 123: ...123 Espas 20I D812913 10598_02 ...
Страница 124: ...ITALY ...