background image

VALUE

FUNCTION

0

START   EXTERNAL

1

START   INTERNAL

2

OPEN

3

CLOSE

4

5

TIMER (HOLD OPEN)

6

7

8

9

10

SAFETY EDGE (bar)

11

OBSTRUCTION, SUPERVISED

12

OPENING OBSTRUCTION, SUPERVISED

13

CLOSING OBSTRUCTION, SUPERVISED

14

SAFETY EDGE, SUPERVISED

IC & EXPI LOGICS

IC 1 & 2 EXPI 1 EXPI 2

PED (PARTIAL OPEN)

TIMER PED (HOLD PARTIAL OPEN)
OBSTRUCTION (phot)
OPENING OBSTRUCTION (phop)
CLOSING OBSTRUCTION (phcl)

error

description

error

description

er20

motor 2 improper encoder movement detected

er35

motor 1 obstacle detection during opening

er22

motor 2 opposite movement

er36

motor 1 obstacle detection during closing

er25

motor 1 improper encoder movement detected

er37

motor 1 obstacle detection during opening slowdown

er27

motor 1 opposite movement

er38

motor 1 obstacle detection during closing slowdown

er30

motor 2 obstacle detection during opening

er40

thermal overload

er31

motor 2 obstacle detection during closing

er61

operating on battery power

er32

motor 2 obstacle detection during opening slowdown

error setting limits

er33

motor 2 obstacle detection during closing slowdown

erf9

lock output overload

ersw

V A L U E

0

1

2

L O G I C

4-STEP

3-STEP

2-STEP

O PEN I N G

STOPS + TCA STOPS + TCA REVERSES

C L O S I N G

STOPS

REVERSES

REVERSES

STEP-BY-STEP LOGICS

VALUE

FUNCTION

0

2ND CHANNEL RECEIVER OUTPUT

1

GATE OPEN LIGHT. output active WHEN GATE IS NOT CLOSED. FLASHES WHILE CLOSING

2

COURTESY LIGHT. output active DURING AND FOR 90 SECONDS AFTER OPERATION.

3

GATE NOT CLOSED. output active UNTIL CLOSE LIMIT IS REACHED

4

START OF CYCLE. output active FOR 1 SECOND AT THE BEGINNING OF EACH CYCLE

5

GATE OPEN ALARM. output active IF GATE IS HELD OPEN FOR MORE THAN DOUBLE THE TIMER TO CLOSE TIME

6

GATE RUNNING. output active WHILE MOTORS ARE POWERED

7

SOLENOID LOCK. output active FOR 2 SECOND AT THE BEGINNING OF OPEN CYCLE

8

MAGNETIC LOCK. output active WHEN GATE IS CLOSED

9

AUX & expo LOGICS

TRAFFIC LIGHT CONTROL (EXPANSION BOARD OUTPUT WITH TLB BOARD ONLY)

*note - when the expansion board
input 1 (expi 1) is set to values 11 ~ 14,
the expansion board input 2 (expi 2)
automatically becomes the
supervision circuit (fault).

advanced programming of inputs and outputs

DOWN

ENTER

UP

escape

navigating the programming menu

button

navigation

value edit

[+]

scrolls up

increase value

[-]

scrolls down

decrease value

enter

enter value

[+] & [-]

escape

escape

[ok]

press the [ok] button rapidly twice to enter programming

VALUE

FUNCTION

DESCRIPTION

0

OBSTRUCTION SENSOR INPUT, NON-CONTACT 

1

OBSTRUCTION SENSOR INPUT, NON-CONTACT, supervised (fault active)

2

OPENING OBSTRUCTION SENSOR INPUT, NON-CONTACT 

3

OPENING OBSTRUCTION SENSOR INPUT, NON-CONTACT, supervised (fault active)

4

CLOSING OBSTRUCTION SENSOR INPUT, NON-CONTACT 

5

CLOSING OBSTRUCTION SENSOR INPUT, NON-CONTACT, supervised (fault active)

6

BAR

SAFETY EDGE (CONTACT OBSTRUCTION) INPUT

7

BAR TEST

SAFETY EDGE (CONTACT OBSTRUCTION) INPUT, supervised (fault active)

8

BAR 8K2

SAFE LOGICS

PHOT

PHOT TEST

PHOT OP

PHOT OP TEST

PHOT CL

PHOT CL TEST

SAFETY EDGE (CONTACT OBSTRUCTION) EOL RESISTOR SUPERVISED INPUT

common error codes

MAIN

SELECTION

DESCRIPTION

DEFAULT

RANGE

PARAM >

OPEN DELAY TIME

Motor 2 opening delay in seconds

1

0-10

Motor 1 closing delay in seconds

1

0-10

TCA

Auto-close time adjustment in seconds

10

1-180

Traffic zone clear time adjustment in seconds

40

1-180

Slowdown starting distance from end of open travel expressed in percentage

10

0-50

Slowdown starting distance from end of close travel expressed in percentage

10

0-50

Slowdown starting distance from end of open and close travel expressed in percentage

15

0-50

OP. FORCE

Percentage of opening force exerted over the AUTOSET value before obstruction is sensed 

50

1-99

Percentage of closing force exerted over the AUTOSET value before obstruction is sensed 

50

1-99

OP SPEED

Motor opening speed expressed in percentage

99

15-99

CL SPEED

Motor closing speed expressed in percentage

99

15-99

SLOW SPEED

Slowdown speed expressed in percentage from maximum speed.

25

15-99

LOGIC >

MOTOR TYPE

1=Eli 250; 2=Phobos BT, 3=Igea BT

0

0-3

TCA

Timer to Close Automatically. 0=OFF / 1=ON

0

0-1

Closes when sensors are cleared. 0=OFF / 1=ON

0

0-1

STEP-BY-STEP MOVEMENT *

Determines how the system reacts when a START command is received during operation

0

0-2

Gate running output (AUX value=6) closes 3 sec. before gate movement. 0=OFF / 1=ON

0

0-1

HOLD-TO-RUN

Requires continuous OPEN or CLOSE command input for gate to operate. 0=OFF / 1=ON

0

0-2

Ignores START input during the opening cycle. 0=OFF / 1=ON

0

0-1

Ignores the START input while counting down for automatic closing. 0=OFF / 1=ON

0

0-1

Ignores the START input during the closing cycle. 0=OFF / 1=ON

0

0-1

RAM BLOW C. OP

Pushes gate against physical stop before opening

0

0-1

RAM BLOW C. CL

Pushes gate against physical stop before closing

0

0-1

BLOC PERSIST

Hourly push against physical stop

0

0-1

Pushes gate against physical stop for .5 seconds after close limit has been reached.

0

0-1

ICE

Continuous force learning on every operation. 

0

0-1

1 MOT. ON

Single Motor operation. 0= (2)motors; 1=(1)motor.

0

0-1

OPEN IN OTHER DIRECT.

0 = Pull to open; 1 = Push to open

0

0-1

SAFE 1 *

0

0-8

SAFE 2 *

Configuration of safety input terminal 74. Defaulted as Bar (Safety Edge)

6

0-8

Configuration of command input terminal 61. Defaulted as Start E

0

0-6

4

0-6

AUX 3 *

0

0-8

FIXED CODE

Rolling code defeat. 0 =  rolling code; 1 = fixed code

0

0-1

Quick remote programming. 0 = disabled; 1 = enabled

1

0-1

SERIAL MODE

0 = Slave unit; 1 =  Master unit

0

0-1

ADDRESS

Unit's network identification number.

0

0-127

Configuration of Expansion board input 1. Defaulted as Start command.

1

0-14

Configuration of Expansion board input 2. Defaulted as Start command.

0

0-10

EXPO 1 *

Configuration of Expansion board output 1. Defaulted as Traffic light control..

9

0-9

EXPO 2 *

Configuration of Expansion board output 2. Defaulted as Traffic light control..

9

0-9

Red light flashes for 3 sec. at every start. 0 = Off; 1 = On

0

0-1

TRAFFIC LIGHT RED LAMP ALWAYS ON

Red light remains on when gate is closed. 0 = Off; 1 = On

0

0-1

RADIO >

ADD START

Learns transmitter button as START command

ADD 2CH

ERASE 64

Erase complete memory

COD RX

Show receiver ID Code

WK

W LINK. 

DEFAULT

Restores board to factory settings. No effect on RADIO

LANGUAGE >

Italian
French
German

ENG

English

ESP

Spanish

AUTOSET

Operates motor(s) several times and automatically adjust its FORCE settings

L. SW ADJ

Limit of travel adjustment. Only available with type 4 and 5 motors

STAT >

Displays board firmware version.

N. CYCLES

Displays number of hundreds of cycles (001=100; 010=1000; 100=10,000)

N. REMOTES

Displays the number of remotes in memory.

ERR

Displays the last 30 board errors in descending order.

PASSWORD

Password setting for wireless programmer

CLS DELAY TIME

TRF. LGHT.CLR. T

OP. DIST. SLOWD

CL. DIST. SLOWD

DIST. DECEL

CLS. FORCE

FAST CLS.

PRE-ALARM

IBL OPEN

IBL TCA

IBL CLOSE

PRESS SWC

Configuration of safety input terminal 72. Defaulted as Phot (Obstruction)

IC 1 *

IC 2 *

Configuration of command input terminal 62. Defaulted as Ped (Partial open)
Configuration of auxiliary output terminals 26 & 27. Defaulted as 2

nd

 channel contacts.

RADIO PROG

EXPI 1 *

EXPI 2 *

TRAFFIC LIGHT PREFLASHING

Learns transmitter button as 2

nd

 channel

ITA

FRA
DEU

VERS

www.BFTGateOpeners.com  |  (800) 878-7829  |  [email protected]