SECTION 2
INSTALLATION OF FIRE
2.1
UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging, check
the contents as listed below :-
NOTE : DO NOT UNDER ANY CIRCUMSTANCES USE THIS APPLIANCE IF THE GLASS PANEL IS
BROKEN OR NOT SECURELY FIXED TO THE FIREBOX.
Packing Check List - All Models
1 off
Combustion chamber / burner
1 off
Boxed ceramic fuel-bed set (packed inside combustion chamber)
1 off
Loose items pack – containing :-
1 off handset (RC models only)
5 off AA batteries (RC models only)
3 off AA batteries (EFC models only)
1 off Installation / user manual
1 off guarantee card
1 off cable fixing kit
1 off grommet
1 off bag of vermiculite
1 off bag of embaglow
2.2
INSTALLING THE FIRE BOX
Establish which type of flue you are intending to install the fire in to :-
225 x 225mm (9 inch x 9 inch) brick built chimneys, 175mm (7 inch) diameter
lined brick or stone flue, or insulated pre-fabricated metal flue box to
B.S. 715.
When installing into 125mm (5 inch) diameter lined brick or stone flue, or
insulated pre-fabricated metal flue box to B.S. 715, the restrictor baffle must
not be fitted.
A spillage test must always be carried out to check satisfactory
clearance of flue products, regardless of the type of flue the
appliance is being fitted to.
9