SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a GAS
SAFE registered engineer.
This is a condition of the guarantee schemes.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for a positive up-draught in the
chimney. To access the debris collection void a removeable plate is positioned on
the rear face of the firebox box behind the burner. The oxypilot on the burner unit
must also be changed as a condition of the guarantee. The condition of the
fuel-bed should be checked and
if necessary the whole item should be
replaced with a genuine replacement item.
The burner assembly is designed to
be removed as a complete unit for ease of access.
After any servicing work a
gas tightness check must always be carried out.
BEFORE ANY SERVICING WORK IS CARRIED OUT ENSURE THE PRODUCT
HAS BEEN DISCONNECTED FROM THE ELECTRICITY SUPPLY. ALL
ELECTRICAL REPAIR WORK MUST BE CARRIED OUT BY A COMPETENT,
QUALIFIED ELECTRICIAN.
4.1
Removing the burner assembly from the fire.
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the glass assembly, remove the ceramic logs and vermiculite.
4.1.3
Lift the burner tray clear, then unscrew and remove the eight off screws
which hold the burner in position & then disconnect the main
Isolate the gas supply and remove the supply pipe from the appliance
inlet elbow. Disconnect the wiring connector from the V module.
4.1.4
To refit the burner assembly, locate the burner unit and refit the eight off
screws. Re-connect the wiring connector. Refit the burner tray. Refit the
gas supply pipe and carry out a gas tightness test. Refit the fuel-bed
referring to section 3 for the correct log positions. Re-fit the glass frame
assembly, grill (held in position by two screws) and side trims.
4.2
Removing the gas control valve from the fire.
4.2.1
Remove the burner from the combustion chamber as described in
section 4.1 above.
4.2.2
Disconnect the inlet, outlet, pilot pipes and thermocouple connection
from the control valve.
4.2.3
Replace in reverse order and carry out a gas tightness test.
33