Door control on/off
If door contacts are used and this function is
activated, a warning signal sounds during the
time set as door held warning time, i.e. when
the opening time has expired and the door is
still open.
If the door held warning time expires and the
door is still open, the alert output is activated
(if the Alert function is activated). This also hap-
pens if the door is forced open.
This is how to activate Door control:
Press B and enter the password.
Enter
A67
.
Enter 1.
Press B to leave programming mode.
To deactivate Door control, press 0 in step 3
instead.