Beverage-Air WTRCS Series Скачать руководство пользователя страница 21

User Manual for WTRCS Refrigerators 

Beverage-Air

Rev. 06/20

Beverage-Air

21

LIMITED WARRANTY

WARRANTY (Warranty valid in USA and Canada)

THREE (3) YEAR PARTS AND LABOR WARRANTY: 

Beverage-Air Corporation warrants to the original 
purchaser of Beverage-Air branded equipment, including 
all parts thereof, that such equipment is free from defects 
in material and workmanship, under normal use, proper 
maintenance, and service as indicated by Beverage-Air 
installation and operation instructions, for a period of three 
(3) years from the date of installation, or thirty-nine (39) 
Months from the date of shipment from the manufacturer, 
whichever is earlier.

ADDITIONAL FOUR (4) YEAR COMPRESSOR PART 
WARRANTY*:  In addition to the warranty set forth above, 
Beverage-Air warrants the hermetically/semi-hermetically 
sealed compressor (part only) for an additional FOUR (4) 
years beyond the first three (3) years warranty period; 
not to exceed eighty-seven (87) months from the date of 
shipment from Beverage-Air, provided upon receipt of the 
compressor, manufacturer examination shows the sealed 
compressor to be defective. This extended warranty does 
not cover freight for the replacement compressor or freight 
for the return of the failed compressor. 

* Units shipped after 03/01/2020.  Previous warranty 
applies to units shipped prior.   

EXCEPTIONS:

CT96 Models carry a one (1) year parts and labor warranty, 
limited to fifteen (15) months from date of shipment 
from Beverage-Air.  These are excluded from additional 
compressor warranty.   

SR/SF (Slate) models carry a two (2) year parts and labor 
warranty, limited to twenty-seven (27) months from date of 
shipment from the Beverage-Air. 

Blast Chillers carry a three (3) year parts and labor 
warranty; additional two (2) years compressor part only. 

Units installed in Residential applications will be not 
covered under this warranty.  Units are intended for 
Commercial use only.         

                                                                        

BEVERAGE-AIR 

Also, this extended compressor-part only warranty does 
NOT apply to any electrical controls, condenser, evaporator, 
fan motors, overload switch, starting relay, capacitors, 
temperature control, filter/drier, accumulator, refrigeration 
tubing, wiring harness, labor charges, or supplies which are 
covered  by  the  warranty  above.                                                                                                                     

Normal wear type parts, such as light bulbs/lamps and 
gaskets are not covered by this warranty. For the purpose 
of this warranty, the original purchaser shall be deemed to 
mean the individual or company for who the product was 
originally installed.

Our obligation under this warranty shall be limited to 
repairing or replacing, including labor, any part of such 
product, which proves thus defective. Beverage-Air 
reserves the right to examine any product claimed to be 
defective.

The labor warranty shall be for self-contained units 
only and for standard straight time, which is defined as 
normal service rate time, for service performed during 
normal working hours. Any service requested outside of 
a servicer's normal working hours will be covered under 
this warranty at the normal rate and any additional 
overtime rate will be at the responsibility of the equipment 
purchaser.

Any part or accessory determined to be defective in the 
product should be returned to the company within thirty 
(30) days under the terms of this warranty and must be 
accompanied by a record of the cabinet model, serial 
number, and identified with a return material authorization 
number (RMA#) issued by the manufacturer.

Special installation/applications, including remote locations, 
are limited in coverage by this warranty. Any installation 
that requires extra work, and/or travel, to gain access to the 
unit for service is the sole responsibility of the equipment 
purchaser.

Improper operation resulting from factors, including but not 
limited to, improper or negligent cleaning and maintenance, 
low voltage conditions, inadequate wiring, outdoor use 
(unless otherwise specified) and accidental damage are no 
manufacturing defects and are strictly the responsibility of 
the purchaser.

Содержание WTRCS Series

Страница 1: ...G INSTRUCTIONS for all Hydrocarbon WTRCS Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 176A Rev 06 26 2020 SEE BACK COVER F...

Страница 2: ...formation is located with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may limit or void the warranty Bever...

Страница 3: ...ngers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other f...

Страница 4: ...altered in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjec...

Страница 5: ...20 WTRCS72HC 1 72 x 34 3 4 x 24 3 8 2 4 5 5 15P R 290 90 WTRCS84HC 1 84 x 34 3 4 x 26 5 8 2 4 4 5 5 15P R 290 90 WTRCS96HC 1 96 x 34 3 4 x 24 3 8 2 4 5 5 15P R 290 90 WTRCS112HC 1 96 x 34 3 4 x 24 3 8...

Страница 6: ...0 Left 0 Right 1 Rear 3 13 16 Below Floor Load the floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit...

Страница 7: ...te direction 2 None of the threads on the leg or caster stem should be visible once screwed in 3 Tilt the cabinet in one direction approximately 8 and block it securely with pieces of 2x4 lumber or ot...

Страница 8: ...5 15P plug If the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This unit must be grounded Do not use extension cords and do not disable or...

Страница 9: ...efrost Push and immediately release the melting or defrost button for a manual defrost Note Holding the defrost button in too long will shut the controller off The internal fan will be on when the com...

Страница 10: ...off when the Compressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously in refrigerators When the u...

Страница 11: ...Set Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ESC Quick press and release A...

Страница 12: ...anel Connections Changing the Set point Electronic Controller Alarms The alarm condition is always signaled by the alarm icon To turn off the relative icon will continue flashing NOTE If alarm exclusi...

Страница 13: ...relay beep the buzzer Door open alarm uHi Line voltage is higher than Cop uHi Always Blink uHi If configu red cut in alarm relay beep the buzzer High voltage alarm uLi Line voltage is higher than Cop...

Страница 14: ...isconnect power to the cabinet at the main power supply circuit breaker 3 Remove loose food particles from interior floors walls and ceiling 4 Scrub all interior surfaces and drawer gaskets with a war...

Страница 15: ...inet follow these instructions 1 Open the drawer to full extension 2 Push the white locking tabs forward on both sides of the drawer 3 Press down the back of the tabs 4 Slide the drawer out of the cab...

Страница 16: ...d compressor failure and may result in loss of property Failure to keep the condenser coil clean may void the limited warranty 1 Unplug unit from power supply 2 Remove the bottom screw from the front...

Страница 17: ...small amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Dis...

Страница 18: ...temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No...

Страница 19: ...e venting MUST be in an area free from flame or spark It must be near an opend window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration ser...

Страница 20: ...ICE TECH WIRING DIAGRAM WHITE 2 1 BLACK EVAP FANS SEE CONTROLLER DETAIL 2 3 SEE CONTROLLER DETAIL WHITE BLACK BLACK WHITE COMPRESSOR DETAIL 115V 1PH COMP CONDENSER FAN C OL R S S CURRENT RELAY 1 M 2 4...

Страница 21: ...RAGE AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filter...

Страница 22: ...T AND WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall no...

Страница 23: ...______________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name ____________________________________________...

Отзывы: