UNPACKING AND SET UP

CAUTION

Risk of personal injury.  
Unit must be securely supported 
while attaching casters or legs.

WARNING

Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is 
suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim. 
Do NOT contact the manufacturer.

Uncrating

Tools Needed: ¾” box wrench, adjustable wrench, level, 
flat head screw driver, and box cutter.

1.  First, remove the cardboard top capping, all clear 

tape, and all staples including those at the bottom of 
the cardboard carton and skid.

2.  Next, start from the top of the carton. Using the box 

cutter, carefully make one continuous cut to the 
bottom of the skid. Remove cardboard carton and 
discard.

3.  Then, move unit as close to final position as possible 

before removing the skid.

4.  Remove the brackets securing the unit to the skid. 

Note: The skid must be removed before the casters or 
legs can be attached.

Do NOT tip unit on its front or sides. If tipped onto the 
back, unit must not be started for 3 hours.

Skid Removal and Caster Attachment

Tip the unit forward and remove the skid. 

1.  Remove the shipping bolts using the ¾” box wrench 

while cabinet is held in one direction. Repeat the process 

while the cabinet is held in the opposite direction. 

2.  None of the threads on the leg or caster stem should 

be visible once screwed in. 

3.  Tilt the cabinet in one direction approximately 8” and 

block it securely with pieces of 2x4 lumber or other 

suitable material.

4.  Thread the stem casters or legs into the ½ -13 holes in 

the bottom of the cabinet. Tighten by hand as much 

as possible. Some models may already have levelers 

installed. If so, then the levelers will need to first be 

removed and discarded.

5.  Once the caster or leg cannot be turned any further, 

use a 3/4 inch wrench to tighten the nut in between 

the mounting plate and the wheel of the caster until 

snug.

6.  Repeat this procedure with unit secured in the 

opposite direction so as to access the remaining legs/

casters/levelers

7.  If plate casters or legs are installed instead of stem 

casters or legs, then repeat step 3 above and secure 

the plate with either #14 AB screws, or ¼-20 screws, 

depending upon which are required.

8.  If levelers are employed, then repeat step 3 above and 

thread the leveler in place. Then repeat step 6.

Leveling:

Cabinets must be leveled when installed. Level should be 

measured on the headrail.

Failure to level your cabinet may result in door not 

sealing, closing correctly, or condensed water draining not 

draining properly.

For cabinets with legs, rotate the foot of the leg with an 

adjustable wrench to achieve desired height for leveling.

For cabinets with casters, leveling can be achieved by 

placing large washers in between the ½’ stud and the 

holes located on the bottom of the case. 

Do NOT loosen casters to level the 
cabinet. 

Casters MUST be tightly 

secured to cabinet for full strength.

Install or attach any accessories that will be used
Remove any plastic covering the stainless steel.

Содержание PR1HC-1AHS

Страница 1: ...NG INSTRUCTIONS for all Hydrocarbon PR Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 217A Rev B 10 29 2020 SEE BACK COVER F...

Страница 2: ...may limit or void the warranty Beverage Air reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements...

Страница 3: ...ll instructions There are many safety labels and directions on the unit Heed them Watch your fingers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a...

Страница 4: ...is necessary to move the Refrigerator after removal from the skid remove all doors and carefully push the unit at a point of no more than 36 from the bottom to avoid damage CAUTION SAFETY Push ONLY b...

Страница 5: ...part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected to excessive cold May only be...

Страница 6: ...8 4 Half Solid 6 5 5 15P PR2HC 1AS 52 1 8 x 34 3 4 x 84 1 8 Full Solid 6 5 5 15P PR2HC 1BG 52 1 8 x 33 5 8 x 84 1 8 2 Full Glass 6 5 5 15P PR3HC 1AHS 77 3 4 x 34 3 4 x 84 1 8 6 Half Solid 8 5 5 15P R...

Страница 7: ...e floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum product load Ventilation Grille area...

Страница 8: ...d be visible once screwed in 3 Tilt the cabinet in one direction approximately 8 and block it securely with pieces of 2x4 lumber or other suitable material 4 Thread the stem casters or legs into the 1...

Страница 9: ...etention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL...

Страница 10: ...15P plug If the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This unit must be grounded Do not use extension cords and do not disable or...

Страница 11: ...need to be removed 5 Take the hole plugs and insert them into the screw holes where the hinges were originally located on the unit 6 Install the hinge bracket upright on the unit The thick portion of...

Страница 12: ...point before loading it with product Pull down time will vary depending upon the type of unit and ambient conditions Freshly cooked product or otherwise warm product placed into the appliance will als...

Страница 13: ...plugged in and the evaporator has achieved its run set limit The Evaporator Fan is connected to control relay The Evaporator Fan runs continuously When the unit is plugged in and the evaporator has a...

Страница 14: ...input OFF Otherwise 3 Fans Permanently On Fans active OFF Otherwise 4 Reduced SET Economy Permanently On Energy saving active Blinking Reduced setpoint active OFF Otherwise 5 Alarm Permanently On Alar...

Страница 15: ...isplay connection 15 16 17 LIGHT STANDBY UP DOWN ESC SET Enter Press and Hold Press and Hold Press and Release Press and Release Press and Release Press and Release Long press 5 sec Toggles light on a...

Страница 16: ...ve Key pad will beep when unlocked and normal key pad operations performed Setting the Operating Set Point To change the operating set point press and release the set button to enter the machine menu...

Страница 17: ...Press the set button to display the value and use the up or down button to change the value Once the value has been selected use the escape button to confirm the new value and return the pervious men...

Страница 18: ...User Manual for PR Refrigerators Beverage Air Rev 10 20 Beverage Air 18...

Страница 19: ...ic SP1 Att Afd HA1 PAO dAO OAO tA1 AH2 HIGH temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 AL2 LOW temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 EA E...

Страница 20: ...nse with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related items a...

Страница 21: ...5 To reinstall the front panel line up the keeper screws behind the panel and firmly pull downwards 6 Reinstall the screws on the top corners 7 Examine condenser surface if dusty brush and vacuum the...

Страница 22: ...mall amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Disc...

Страница 23: ...emp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No...

Страница 24: ...venting MUST be in an area free from flame or spark It must be near an opend window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration servi...

Страница 25: ...AY 13 14 RED CABINET LIGHTS POWER SUPPLY BLACK WHITE 24VDC HIGH CURRENT DIODE WHT COMPRESSOR DETAIL START RELAY 10 COMP CONDENSER FAN C R S 2 4 OL 1 R C S C HIGH PRESSURE LIMIT SWITCH NOT ALL MODELS B...

Страница 26: ...AGE AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filter...

Страница 27: ...AND WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall not...

Страница 28: ..._____________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _____________________________________________...

Отзывы: