Beverage-Air HBF Series Скачать руководство пользователя страница 23

User Manual for HBF Freezers 

Beverage-Air

Rev. 0/820

Beverage-Air

23

LIMITED WARRANTY

WARRANTY (Warranty valid in USA and Canada)

THREE (3) YEAR PARTS AND LABOR WARRANTY: 

Beverage-Air Corporation warrants to the original 
purchaser of Beverage-Air branded equipment, including 
all parts thereof, that such equipment is free from defects 
in material and workmanship, under normal use, proper 
maintenance, and service as indicated by Beverage-Air 
installation and operation instructions, for a period of three 
(3) years from the date of installation, or thirty-nine (39) 
Months from the date of shipment from the manufacturer, 
whichever is earlier.

ADDITIONAL FOUR (4) YEAR COMPRESSOR PART 
WARRANTY*:  In addition to the warranty set forth above, 
Beverage-Air warrants the hermetically/semi-hermetically 
sealed compressor (part only) for an additional FOUR (4) 
years beyond the first three (3) years warranty period; 
not to exceed eighty-seven (87) months from the date of 
shipment from Beverage-Air, provided upon receipt of the 
compressor, manufacturer examination shows the sealed 
compressor to be defective. This extended warranty does 
not cover freight for the replacement compressor or freight 
for the return of the failed compressor. 

* Units shipped after 03/01/2020.  Previous warranty 
applies to units shipped prior.   

EXCEPTIONS:

CT96 Models carry a one (1) year parts and labor warranty, 
limited to fifteen (15) months from date of shipment 
from Beverage-Air.  These are excluded from additional 
compressor warranty.   

SR/SF (Slate) models carry a two (2) year parts and labor 
warranty, limited to twenty-seven (27) months from date of 
shipment from the Beverage-Air. 

Blast Chillers carry a three (3) year parts and labor 
warranty; additional two (2) years compressor part only. 

Units installed in Residential applications will be not 
covered under this warranty.  Units are intended for 
Commercial use only.         

                                                                        

BEVERAGE-AIR 

Also, this extended compressor-part only warranty does 
NOT apply to any electrical controls, condenser, evaporator, 
fan motors, overload switch, starting relay, capacitors, 
temperature control, filter/drier, accumulator, refrigeration 
tubing, wiring harness, labor charges, or supplies which are 
covered  by  the  warranty  above.                                                                                                                     

Normal wear type parts, such as light bulbs/lamps and 
gaskets are not covered by this warranty. For the purpose 
of this warranty, the original purchaser shall be deemed to 
mean the individual or company for who the product was 
originally installed.

Our obligation under this warranty shall be limited to 
repairing or replacing, including labor, any part of such 
product, which proves thus defective. Beverage-Air 
reserves the right to examine any product claimed to be 
defective.

The labor warranty shall be for self-contained units 
only and for standard straight time, which is defined as 
normal service rate time, for service performed during 
normal working hours. Any service requested outside of 
a servicer's normal working hours will be covered under 
this warranty at the normal rate and any additional 
overtime rate will be at the responsibility of the equipment 
purchaser.

Any part or accessory determined to be defective in the 
product should be returned to the company within thirty 
(30) days under the terms of this warranty and must be 
accompanied by a record of the cabinet model, serial 
number, and identified with a return material authorization 
number (RMA#) issued by the manufacturer.

Special installation/applications, including remote locations, 
are limited in coverage by this warranty. Any installation 
that requires extra work, and/or travel, to gain access to the 
unit for service is the sole responsibility of the equipment 
purchaser.

Improper operation resulting from factors, including but not 
limited to, improper or negligent cleaning and maintenance, 
low voltage conditions, inadequate wiring, outdoor use 
(unless otherwise specified) and accidental damage are no 
manufacturing defects and are strictly the responsibility of 
the purchaser.

Содержание HBF Series

Страница 1: ...PERATING INSTRUCTIONS for all Hydrocarbon HBF Freezer Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 157A 8 9 2020 SEE BACK COVER FOR WAR...

Страница 2: ...ED Your warranty registration information is located with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may...

Страница 3: ...rs There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other flam...

Страница 4: ...s necessary to move the Refrigerator after removal from the skid remove all doors and carefully push the unit at a point of no more than 36 from the bottom to avoid damage CAUTION SAFETY Push ONLY bel...

Страница 5: ...Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected to excessive c...

Страница 6: ...1 4 Full 2 Glass 11 5 15P R 290 150 HBF44HC 1 HG 47 x 33 3 4 x 84 1 4 Half 4 Glass 11 5 15P R 290 150 HBF44HC 1 HS 47 x 33 3 4 x 84 1 4 Full 4 Solid 11 5 15P R 290 150 HBF49HC 1 52 x 33 3 4 x 84 1 4 F...

Страница 7: ...in below Floor Load the floor on which the freezer is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum product load Ventil...

Страница 8: ...or caster stem should be visible once screwed in 3 Tilt the cabinet in one direction approximately 8 and block it securely with pieces of 2x4 lumber or other suitable material 4 Thread the stem caste...

Страница 9: ...5 Install shelves onto clips with the product retention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as...

Страница 10: ...the factory and should not need adjustment however if it was changed the standard setting is 0 F Cautions Care must be taken whenever moving or servicing the unit The refrigerant is contained in a se...

Страница 11: ...Push and immediately release the melting or defrost button for a manual defrost Note Holding the defrost button in too long will shut the controller off The internal fan will be on when the compressor...

Страница 12: ...rator Fan is wired to the Fan Contact The Evaporator Fan turns off when the Compressor is not running and when door is opened while Compressor is running The Evaporator Fan is wired to the Fan Contact...

Страница 13: ...Display Defrost LED Alarm LED On fixed Defrost active On fixed ALARM Present Off Defrost is off Flashing ALARM Silenced Off No Alarm Fan LED Compressor LED On fixed Fan active On fixed Compressor act...

Страница 14: ...brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ESC Quick press and release Activates manual defrost Long press and release Cont...

Страница 15: ...ink Con If configured cut in alarm relay beep the buzzer Condenser alarm dor Door open for more than Always Blink dor If configured cut in alarm relay beep the buzzer Door open alarm uHi Line voltage...

Страница 16: ...e with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related items and...

Страница 17: ...d damaging the fins Use care to not disturb the wires connected to the controller Note If the coil is greasy the coil will need to be cleaned with coil cleaner and that should be left to an experience...

Страница 18: ...ll amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discol...

Страница 19: ...p control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No co...

Страница 20: ...n area free from flame or spark It must also be in a well ventilated area with a nearby open window or door A sign noting service of a system containing propane must be attached to the unit during ref...

Страница 21: ...FACE HEATER GLASS DOOR HEATER NOT ALL MODELS 1 SEE CONTROLLER DETAIL 2 SEE CONTROLLER DETAIL SEE CONTROLLER DETAIL SEE CONTROLLER DETAIL D I YELLOW RED BALLAST DRAIN TUBE HEATER 6 5 2 2 LED LED PS 4...

Страница 22: ...G S L E D O M L L A T O N 4 2 L I A T E D R E L L O R T N O C E E S L I A T E D R E L L O R T N O C E E S L I A T E D R E L L O R T N O C E E S I D W O L L E Y D E R D E R T S A L L A B R E T A E H E...

Страница 23: ...E AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filter dr...

Страница 24: ...D WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall not be...

Страница 25: ...___________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _______________________________________________...

Отзывы: