In order to set the program to run continuously for
24hrs, please make sure the duration of the program
is set to 00:00 and 23:59 as indicated in figure 1.
1
. Press the ENT button, make sure Monday is
selected.
2
. Press the ENT button again, the number should
blink. You can change the duration by using the
arrows (Right arrow to select the number you want to
change and the up arrow to change the actual value).
Set the duration to: Change F -> 00:00
Change T -> 23:59
3
. Press ENT again
Note: if you wait more than few seconds, the
programming mode will stop: if that happens, please
repeat the process by pressing the ENT button twice
again.
STEP 1 - Set the duration of the program
BA-1000 Programming Instructions
STEP 2 - Select the program that best suits your needs:
1
. Press the ENT button twice
2
. Click on the right arrow 4 times until you reach W
and P.
3
. Use the Up arrow to change the values.
Set values to:
W : 16
P : 720
(In our newest model instead of W and P you’ll find 01,
you won’t need to change the actual value).
4
. Press ENT again
Program #1 (6 months)
Figure 1
Figure 2
Note: The duration of the programs correspond to the lifetime of
the Refill Bottle.