BT-532C User manual
38
Name
Set One-dimension bar code width
Format
ASCII
:
GS w n
Decimal
:
29 119 n
Hexadecimal
:
1D 77 n
Description
Setting bar code unit is n,
the meaning of the parameters n as follows:
Parameter range 1 ≤ n ≤ 6
Default
n = 2
Supporting
model
All
Notes
When ESC@,resetting printer,power off,the command will failure.
Usage example
N/A
Print One-dimension bar code
Name
Print One-dimension bar code
Format
(A)
ASCII
:
GS k m [d]k NUL
Decimal
:
29 107 m [d]k NUL
Hexadecimal
:
1D 6B m [d]k NUL
(B)
ASCII
:
GS k m n [d]k
Decimal
:
29 107 m n [d]k
Hexadecimal
:
1D 6B m n [d]k
Description
Print One-dimension bar code,
the meaning of all parameters as follows:
m is encode mode.
n is the length of encode data, only for (B),the difference between (A) and (B)
is :(A) end with NULL,AND (B) use the length of indication data.
[d]k is the bar code data.
K is the length of bar code data,just a sign not transmission.