![BETTCHER INDUSTRIES Whizard Power Knife 109496 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/bettcher-industries/whizard-power-knife-109496/whizard-power-knife-109496_operators-manual_2743093018.webp)
Operating
Bettcher Industries, Inc.
Whizard® Power Knife Manual
Instructions
October 21, 2020
Page 14
9.2 Cleaning the Motor Unit
The motor unit may be cleaned with soap and water.
Do not submerge Motor Unit in water.
Damage to the motor will result.
Unplug the Motor Unit when cleaning or servicing.
9.3 Cleaning the Power Supply
Risk of shock hazard. Disconnect from line voltage before servicing. The Power Supply
enclosure may be wiped clean, but
do not submerge unit in water. Damage to the Power
Supply will result.
9.4 Daily Cleaning
For cleaning, the
lever
may be taken off by
removing the two
shoulder screws
. The
flat
spring
may be removed from its stud. Do not
remove the other screws. The
strain relief
may also be unscrewed for cleaning. When
reassembling, the hole in the flat spring fits
on the molded stud and its other end is
captured by the tab at the end of the lever.
Risk Of Shock Hazard - Disconnect From Line Voltage Before Servicing.
BETTCHER INDUSTRIES, INC. PROUDLY
MANUFACTURES QUALITY PARTS FOR YOUR
BETTCHER EQUIPMENT. FOR OPTIMUM
PERFORMANCE OF YOUR BETTCHER EQUIPMENT, USE
ONLY PARTS MANUFACTURED BY
BETTCHER INDUSTRIES, INC.