ERROR
CODE
ERROR DESCRIPTION
FAULT ANALYSIS AND TREATMENT
working normally.If the motor doesˊt turn,change the
motor;If there is no “OFF” signal,adjust the gap between
the sensor and door or replace sensor.
Error 9
Ball chute/ball pipe
(
KL0002451)
jam
1
、
Check if there is any foreign matter stuck in the ball
pipe and remove if there is
;
2
、
Empty the ball pipe ,enter the “browse all inputs”
test,check whether there are green items in L
、
M
、
N, and
change the corresponding sensor if there are.
3
、
Check if the position of sensors moved away if issue
remains..
4
、
Check the wiring if issue remains.
5
、
Check the main board/mother board if issue remains.
4.2.
Other fault analysis and treatment
1.The ball is stuck so frequently that the wind cannot blow it into the bin.
A-Check whether the weight of the ball exceeds 8g or not.
B-Check whether the voltage of the site is too low.
C-Check whether the fan inlet and outlet are blocked,if yes,clean up.
D-Check if the fan has accumulated and clean up if there is.
2.After each game,the blower has been working for a period of time.
A-Check if there is ball lingering in the end of the game ,if there is,reduce the ball or increase
the game time.
B-Check the bottom door’s test sensor whether there is debris or dust.If there is,clean it up.
3.Lattice screen confused or irregular flashing
A-Check whether the wire is loose,if yes,plug the wire set.
B-Replace the display screen.
4.Unable to enter double PK mode,and “
!
”on screen
A-One side of the machine is in shutdown state or fault,if any, please use after repair.
B-Check the communication cables on both sides to see if they are loose.If so,please lock
them tightly.
C-Check the “SW3-6”on both motherboards.The normal state is :left is“ON” ,and right
is“OFF”
D-Check that the game parameters on both sides are consistent.
5.No winner wan shown after PK mode;the winner haven't more tickets.
A-Check that the game parameters on both sides are consistent.In the case of inconsistency,it
is impossible to conduct a double PK.
Содержание BALL MADNESS
Страница 1: ...BALL MADNESS Operator Manual V1 1 ...
Страница 34: ... BALL MADNESS Manual V1 1 33 6 3 Wiring schematic ...
Страница 35: ... BALL MADNESS Manual V1 1 34 ...
Страница 36: ... BALL MADNESS Manual V1 1 35 ...
Страница 37: ... BALL MADNESS Manual V1 1 36 ...
Страница 38: ... BALL MADNESS Manual V1 1 37 ...