Betafence Publifor 3D Pro XL Скачать руководство пользователя страница 3

Main components of standard Publifor module :

N

°

1 Metal basement

L 2530 x W 700 x H 805 mm

N

°

2 Vertical posts

80 x 60 x 3 H 2547 mm

N

°

2 Horizontal posts

80 x 60 x 2 W 2405 mm

3

80 x 60 x 2 W 2405 mm

N°4 Connection plates

140 x 80 x 75 mm - thickness 5 mm

N°2 Panels

H 1630 x L 2500 mm

N°32 polyamide  N°32 M6L40 
screws

N°8 M8L80

(bolts with washers and self-

breaking nuts)

N°6 M 30

Содержание Publifor 3D Pro XL

Страница 1: ...Publifor Installation Manual Security Barrier System Sales Release Version Apr 16...

Страница 2: ...1 Components 2 Steps to assembly the Standard Module Publifor 2...

Страница 3: ...2 Vertical posts 80 x 60 x 3 H 2547 mm N 2 Horizontal posts 80 x 60 x 2 W 2405 mm 3 80 x 60 x 2 W 2405 mm N 4 Connection plates 140 x 80 x 75 mm thickness 5 mm N 2 Panels H 1630 x L 2500 mm N 32 polya...

Страница 4: ...A A Step 1 Position the basement on a plane support Install the vertical posts to the basement using the screws M6L30 N 3 screws are necessary for each post 4...

Страница 5: ...B B Step 2 Install the horizontal post on the top and the T plates using the screws M8 L 80 and washer and self breaking nut N 2 T plates and N 4 screws are necessary for each horizontal post 5...

Страница 6: ...C C Step 3 Fill the basement with concrete and shake it 6...

Страница 7: ...D D Step 4 Install the horizontal post on the bottom and the T plates using the screws M8 L 80 and washer and self breaking nut N 2 T plates and N 4 screws are necessary for each horizontal post 7...

Страница 8: ...E E Step 5 Install the Nylofor 2DS panels on the frame using polyamide clamps and M6L40 screws N 2 panels N 32 polyamide clamps N 32 M6L40 screws are necessary 8...

Страница 9: ...F F Step 6 After the positioning of mobile fence connect the modules together using M10L30 screws and self locking nuts N 2 bolts set to connect N 2 modules 9...

Страница 10: ......

Отзывы: