![Beta 1760/A Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/beta/1760-a/1760-a_manual_2742386011.webp)
EN
11
3.2.3 DC Current
>
Overload Protection: 2mA to 200mA Ranges: F1:F200mA/250V fuse
10A Range: F2:F10A/250V fuse
>
Max. Input Current: mA Jack: 200mA
10A Jack: 10A
>
Voltage Drop: 200mV
Range
Resolution
Accuracy
2mA
1
µ
A
±(1.0% of rdg +3 digits)
20mA
10
µ
A
±(1.0% of rdg +3 digits)
200mA
100
µ
A
±(1.5% of rdg +5 digits)
10A
10mA
±(2.0% of rdg +10 digits)
MultimetroDigitale.book Page 11 Friday, September 26, 2003 6:34 PM