background image

 

8

1464TDIGITAL PRESSURE AND COMPRESSION TESTER

Description

Item 1464T is an instrument which can measure several different types of sensors; hence it can be used to 

measure numerous parameters in the automotive industry. It is fitted with an 80 bar pressure sensor, which can 

be used to perform compression tests in petrol and diesel engines as well oil pressure, low pressure common 

rail circuit and other tests.
A major advantage of item 1464T is that you can purchase several different additional kits to perform other tests 

as well, including the high pressure circuit test in common rail engines. The internal software can be updated by 

the user via USB connection (a PC connected to the Internet is required).
The result of the measurements is displayed on the 5 inch touch screen. The display will be either numeric or 

graphic, depending on the test being performed. 

Item 1464T is fitted with an internal memory, to store the collected data, so that they can later be sent to a 

computer.

Specifications

80 bar sensor 

: precision ratiometric 1% FS (0º÷50º)

Power supply 

: rechargeable battery LiPo 3,7V / 1000mAh

Battery charge 

: via USB connector

Display  : colour TFT, 5”, 480x272 pixels, tactile
Connectivity 

: USB (Windows)

Updatable software  : 

V

Observations

- - The display is a tactile, resistive device; some precision is required so that it can respond. You can press it 

with either your fingers or a non-sharp object – that is, any digital pen specially designed for resistive displays.

- This instrument is fitted with a smart battery charge system. To charge the battery, just connect the instrument 

to a USB port of the computer via the USB cable, or, alternatively, to a USB charger. The upper part accommo-

dates a battery charge indicator which goes on when the battery is charging, and automatically goes out when 

the charge cycle is completed. The instrument can be left permanently connected to the charger; if the battery 

runs down, the charging cycle will start again automatically.

- The software should be updated regularly, so that it can have the latest and best possible characteristics.

Содержание 1464T

Страница 1: ...1464T MODE D EMPLOI GEBRAUCHSANWEISUNG INSTRUCCIONES GEBRUIKSAANWIJZING INSTRUKCJA OBSŁUGI ISTRUZIONI PER L USO INSTRUCTIONS FOR USE INSTRUÇÕES DE USO HASZNÁLATI ÚTMUTATÓ I D NL EN E PL F PT HU ...

Страница 2: ...cted data so that they can later be sent to a computer Specifications 80 bar sensor precision ratiometric 1 FS 0º 50º Power supply rechargeable battery LiPo 3 7V 1000mAh Battery charge via USB connector Display colour TFT 5 480x272 pixels tactile Connectivity USB Windows Updatable software V Observations The display is a tactile resistive device some precision is required so that it can respond Yo...

Страница 3: ...he required option is displayed press the relevant button to select it When using the tester for the first time select first the Configuration option and then the required options When the configuration screen is exited it will be saved automatically As you can see in the picture below you can configure the language the brightness of the screen the volume of the loudspeaker the unit of measurement...

Страница 4: ...e relevant instructions What is the common rail system What is the common rail system The common rail system is one of the most advanced diesel fuel injection systems based on the fuel injected directly into the cylinder direct injection at high pressure 300 2000 bar One of the great advantages of this new system lies in the fact that the nozzles are controlled electronically so an electronic unit...

Страница 5: ...ested The low pressure circuit test is a three step test Test n 1 Description pressure test at high pressure pump inlet Correct value 2 5 bar Results of test n 1 Correct pressure 2 5 bar Go to test n 2 Significantly higher pressure faulty regulator Significantly lower pressure go to test n 2 Test n 2 Description pressure between low pressure pump and filter Correct value 2 5 bar Results of test n ...

Страница 6: ...can be saved when needed by pressing the Save key The term REC will be shown in the upper part of the display Press Save again to store the value The data thus saved can later be sent to a computer via USB connection 80 bar manometer This instrument can measure pressures up to 80 bar like a normal manometer The pressure and maximum reading values will be shown on the display The latter can be rese...

Страница 7: ...avoiding possible negative effects for the environment and people s health and facilitates the recycling of the materials the equipment is made of Illegal disposal of this product on part of the user will give way to the application of such administrative fines as referred to in Italian Legislative Decree n 22 1997 article 50 and following articles of Italian Legislative Decree n 22 1997 WARRANTY ...

Отзывы: