beta sensorik Hansford Sensors HS-620 Скачать руководство пользователя страница 14

HS-620/630 User Guide

                                                                           

- 12 – 

                                           

 

 

                                 

                                                             

QM14 Issue 4 

 

 

5.1. Surface Temperature Measurement 

The temperature sensor measures the average temperature in a circle 
of diameter one-eighth of the distance between the surface and the 
sensor. For example, when the meter is held 1m from a surface, the 
sensor will respond to a 125mm spot diameter on the surface. Thus, the 
measuring distance will define the size surface to be measured. The 
maximum recommended distance from surface to sensor is 2m and 
hence the maximum spot diameter is 250mm. The measurement is 
made as follows:- 
 
Switch on the meter using the 

SEL

 key 

 
Press the 

F/°C

 for the temperature mode   

 
Aim the laser beam at the surface to be measured at a suitable distance 
from the surface, remembering that the temperature sensor spot 
diameter is one-eighth of the distance (ie not the laser spot size). 
 
The temperature reading can be toggled between °F and °C using the 

SEL

 key. Ambient temperature is indicated at the bottom left of the 

display. 
 
Exit the temperature mode by pressing the 

Vib

 or 

Brg

 key

Содержание Hansford Sensors HS-620

Страница 1: ...beta SENSORIK GmbH Hummendorfer Stra e 74 96317 Kronach Telefon 09261 96607 0 Fax 09261 96607 11 briefkasten betasensorik de www betasensorik de beta SENSORIK Vertriebspartner f r Deutschland...

Страница 2: ...r Kit is an ideal low cost entry level vibration monitoring instrument designed for Maintenance Technicians to use on site helping to give protection to important plant machinery The HS 630 adds an ea...

Страница 3: ...HS 620 630 User Guide...

Страница 4: ...______________5 2 4 Overall Vibration Measurement Assessment _______________6 2 5 ISO Machine Groups ___________________________________6 2 6 Bearing Status Check ___________________________________7...

Страница 5: ...2 x Battery Charger Mains Car Manual Carrying Case 1 2 Overall Vibration Mode The meter can measure vibration Velocity in mm s rms Acceleration in g peak and Displacement in m peak to peak When measur...

Страница 6: ...ault icon on the LCD display will disappear Conversely the sensor fault icon will appear if the meter detects a poor sensor connection 2 2 Power On Off Power On Push SEL key only for sec The meter def...

Страница 7: ...e t e m a r a p t n e m e r e t e m SEL e h t h g u o r h t e l g g o t o t B I V y e k s s e r P B I V t e b e l g g o t o t The c i d n i s i e d o m d l o H e r P e d o m G R B e h t n I e d o m e...

Страница 8: ...ter categorises these as ISO1 3 R ISO1 3 F ISO2 4 R ISO2 4 F R and F refer to rigid and flexible machine mounting respectively A label on the back of the meter gives details of the ISO10816 3 machine...

Страница 9: ...toggle through and select the appropriate speed range of the bearing shaft rpm 500 rpm 1000 rpm 2000 rpm 5000 rpm 10000 The meter will then indicate either a tick icon for OK a single bell for vibrat...

Страница 10: ...p stations Electrical motors of all types Blowers or fans The standard classifies machine groups as in section 2 5 and defines vibration levels for each group shown in the chart on page 9 as follows G...

Страница 11: ...o M n s n o c e b g n i r p s r o t a e r g A d r a d n a t s e s s e s s a r s m m 3 n e t n i a m c a m e h t a M e n i h c a m e h t f o d e e p s d e e p s w o l t a e t a r b i v n e t f ft o s...

Страница 12: ...e p o r p t o n s i g n i r a e b e r o t n e s e c a f r u s d e g a m a d b i v g n i r a e b e h T u q e r f h g i h l l a f o s n o i t a r b i v e h T e t a n i m i l e e h t t n e m n g i l a s...

Страница 13: ...un greased bearing BV 2mm s Bearing seizure likely 5 Temperature Mode HS 630 only The HS 630 uses a thermopile infra red sensor to indicate temperature in Deg C or Deg F on the display An alignment la...

Страница 14: ...aximum recommended distance from surface to sensor is 2m and hence the maximum spot diameter is 250mm The measurement is made as follows Switch on the meter using the SEL key Press the F C for the tem...

Страница 15: ...and BV Rule of thumb Temp Range 20 C to 120 C or 5 F to 250 F HS 630 only Laser Guide Red 650nm 1mW IEC 60825 1 compliant HS 630 only Distance Range For Temp measurement 0 to2 metres HS 630 Accuracy 5...

Страница 16: ...eptions rendering the Warranty void are If repair is attempted by unauthorised persons or agents or if the product has been used for purposes for which it was not intended and or subjected to abuse or...

Страница 17: ...4 8 637 7 7 21701 7 7 7 0 7 7 11 7 1 1 7 7 00 017 7 7 0 7 01 1 7 70 1 71 1 7 01 17 7 7 7 7 71 17 7 17 0 7 11 7 17 1 7 10 0 7 7 7 7 1 73 7 7 7 1 73 7 7 7 7 1 74 7 7 17 7 7 7 7 7 7 1 75 78 7 7 7 7 7 1 7...

Страница 18: ..._ Serial No ________________________ Calibrated By _____________________ Date of Calibration _________________ Certificate of Calibration Model No ________________________ Serial No __________________...

Страница 19: ..._ Serial No ________________________ Calibrated By _____________________ Date of Calibration _________________ Certificate of Calibration Model No ________________________ Serial No __________________...

Страница 20: ..._ Serial No ________________________ Calibrated By _____________________ Date of Calibration _________________ Certificate of Calibration Model No ________________________ Serial No __________________...

Страница 21: ..._ Serial No ________________________ Calibrated By _____________________ Date of Calibration _________________ Certificate of Calibration Model No ________________________ Serial No __________________...

Страница 22: ...HS 620 630 User Guide QM14 Issue 4...

Отзывы: