Before investigating any specific electrical problem,
always check:
• The connection between the panel harness and panel
loom. It must be clean, dry and secured with a cable
tie.
• The start battery is connected to the correct terminal
on the starter motor.
• The domestic battery is switched on and connected
to the correct terminals for the secondary domestic
battery charging alternator.
• The battery connections and inspect the condition of
cables from the battery to engine. If in doubt measure
the voltage at the engine.
• If there is a starter alternator charge problem, measure
battery voltage with engine off and again with engine
running, if there is an increase the alternator is
functioning correctly.
ELECTRICAL TROUBLE SHOOTING - ALL CONTROL PANELS
{
Problem
Possible Cause and Solution
No warning lights or buzzer functioning, engine will not
• Battery isolation switch in off position -
switch on.
start or stop
• Starter battery discharged -
charge.
• Engine fuse blown -
check fuse
(above starter motor or
flywheel housing) and replace if necessary.
• Check for wiring faults.
Non function of warning light.
The water temperature
• Disconnect switch wire to non-functioning light: green/
light will not function unless engine is overheating
blue –water temperature
,
white/brown –oil pressure,
or there is a wiring fault
brown/yellow –alternator charge. Reconnect wire
temporarily to another warning light that is functioning;
if wire switches light on replace faulty light.
• Disconnect positive feed to non-functioning light.
Reconnect temporarily with wire from another warning
light that is functioning, if wire switches light on rewire
with new connection.
• If none of the above, check continuity of connections
from panel to the engine.
Water temperature warning light on when engine is not
If engine is cold:
over temperature (Not B or C deluxe panel see table on
• Faulty wiring, check connection and continuity (small
on following page)
green/blue) from switch to panel light. Ensure this
connection is not shorting to earth (ground).
• Faulty temperature switch - if light switches off on
If engine is warm:
• Switch wire connected to large sender terminal of
switch/sender unit. Remove and refit to smaller
(switch) terminal.
Содержание Beta 30
Страница 2: ...Typical Keel Cooling System ...
Страница 25: ...23 ...
Страница 55: ...53 ...
Страница 56: ...54 ...
Страница 58: ...56 ...
Страница 60: ...58 ...
Страница 62: ...60 ...
Страница 63: ...61 ...
Страница 64: ...62 ...
Страница 65: ...63 ...
Страница 66: ...64 ...
Страница 67: ...65 ...
Страница 68: ...66 ...
Страница 69: ...67 ...
Страница 70: ...68 ...
Страница 71: ...69 ...
Страница 72: ...70 ...
Страница 74: ...72 ...
Страница 75: ...73 ...
Страница 76: ...74 ...
Страница 77: ...75 ...
Страница 78: ...76 ...
Страница 79: ...77 ...
Страница 80: ...78 ...
Страница 81: ...79 Notes ...
Страница 87: ...Service Date Responsible 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 ...