15
Remark:
1. The standby button
is still available even keyboard is locked.
2. The keyboard lock will automatically be deactivated under below circumstances:
1) The appliance is put into standby mode by pressing standby button
.
2) The appliance suffers power disconnection.
7. In case of power failure
The device always keeps in memory the temperature, operating mode and weekly personalized
program. In case of power failure, after recovery, set the time again, then the device resumes
back to the mode and temperature before the power failure.
TECHNICAL SPECIFICATIONS
……………………………………
Information requirements for electric local space heaters
Model identifier(s): HE10EBA
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space
heaters only (select one)
Nominal heat output
P
nom
1
kW
manual heat charge control, with
integrated thermostat
[no]
Model
HE10EBA
HE15EBA
HE20EBA
Voltage
230 V ~
230 V ~
230 V ~
Frequency
50 Hz
50 Hz
50 Hz
Rated power
1000 W
1500 W
2000W
Protection
class
II
II
II
IP Protection
IP24
IP24
IP24
Pilot wire
6 orders
6 orders
6 orders
Keyboard lock