BestCode Next Series 8 Technical Manual
October 2022
Page 174 of 290
Prompt Code
Prompt Name
Prompt Description
0E-0001
Viscosity
Ink viscosity is too low.
Solution 1:
Measure ink viscosity, if viscosity is less than 1.1cP, replace the ink.
Solution 2:
Verify the board is the set to the correct Fluidic Generation.
Solution 3:
Lift Makeup pickup tube out of the tank. In Fluidic Screen, Run to 40PSI and watch to see if there is
flow. If the makeup flows, the Makeup Add valve is clogged open and should be cleaned or replaced.
Solution 4:
Replace the Viscometer
Solution 5:
If not using BestCode provided fluids, inspect ink for foaming. This can cause ink to become thin over
time.
Prompt Code
Prompt Name
Prompt Description
0E-0002
Viscosity
Ink viscosity is too high.
Solution 1:
Measure ink viscosity, if viscosity is more than 10cP, replace the ink.
Solution 2:
Verify the board is the set to the correct Fluidic Generation.
Solution 3:
Lift Makeup pickup tube out of the tank. In Fluidic Screen, Run to 40PSI and enable the Makeup Add
valve. Watch to see if there is flow. If the makeup does not flow, the Makeup Add valve is clogged shut
and should be cleaned or replaced.
Solution 4:
Replace the Viscometer
Solution 5:
If not using BestCode provided fluids, inspect ink for foaming. Foam causes ink to seem thick by
increasing the fall time of the ball in the viscometer. Look for air in the Viscometer glass tube.
Prompt Code
Prompt Name
Prompt Description
0E-8001
Not Used
-
Solution 1:
Load new Firmware
Prompt Code
Prompt Name
Prompt Description
0E-8002
Viscosity Fault
Viscosity %6.2f out of valid range
Solution 1:
Check the Ink Viscosity. If it is more than 10cP or less than 1.5cP replace the ink.
Solution 2:
Let the system run until viscosity has returned to normal.
Prompt Code
Prompt Name
Prompt Description
0E-8003
Visc Detect
Viscometer rise not detected.
Solution 1:
Clean or replace the viscometer.
Solution 2:
If not using BestCode provided fluids, inspect ink for foaming. Foam may prevent viscometer from
operating correctly.
Prompt Code
Prompt Name
Prompt Description
0E-8004
Visc Detect
Viscometer fall not detected.
Solution 1:
Clean or replace the viscometer.
Solution 2:
If not using BestCode provided fluids, inspect ink for foaming. Foam may prevent viscometer from
operating correctly.
Prompt Code
Prompt Name
Prompt Description
0F-0001
SmartFill Warn
SmartFill command label not valid.
Solution 1:
Rotate and try again
Solution 2:
Try scanning new SmartFill command label
Solution 3:
Check coax cable connections from the SmartFill cup.
Содержание Next 8 Series
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 142: ...BestCode Next Series 8 Technical Manual October 2022 Page 128 of 290 Photocell Auxiliary Serial ...
Страница 143: ...BestCode Next Series 8 Technical Manual October 2022 Page 129 of 290 USB ...
Страница 144: ...BestCode Next Series 8 Technical Manual October 2022 Page 130 of 290 Collector Information ...
Страница 258: ...BestCode Next Series 8 Technical Manual October 2022 Page 244 of 290 Appendix A Compliance Certificates ...
Страница 259: ...BestCode Next Series 8 Technical Manual October 2022 Page 245 of 290 ...
Страница 264: ...BestCode Next Series 8 Technical Manual October 2022 Page 250 of 290 ...
Страница 268: ...BestCode Next Series 8 Technical Manual October 2022 Page 254 of 290 ...
Страница 276: ...BestCode Next Series 8 Technical Manual October 2022 Page 262 of 290 Using the Molex Crimper ...
Страница 277: ...BestCode Next Series 8 Technical Manual October 2022 Page 263 of 290 ...