background image

11

Transferring Patient

1. Have the patient positioned sitting at the edge of the surface

2. Make sure the seat pads are in folded up position, and move the StandAid lift in front 

of the patient. 

3. Have the patient move their feet onto the foot plate platform and knees/shins are in 

contact with the two knee pads. 

The Bestmove 450 allows access around  wider obstacles such as recliners.  The 

base of the BestMove 450 opens by stepping on the foot pedal.

4. Lock the casters before loading the person onto the lift. 

5. Have the patient grasp the cross bar closest to them and using their own strength 

pull themselves up into a standing position on the footplate platform. If the patient 

needs assistance pulling themselves up. Use a BestTransfer Raising Belt.

6. Lower both of the seat pads to the folded down position.

7. Have the patient lower themselves to a sitting position on the seat pads. If 

BestTransfer Raising Belt is being used. Use the Raising Belt to assist the patient in 

lowering the patient.

8. 

Make sure the patient is firmly sitting in the StandAid

9. Unlock the casters to begin transfer the patient.

10. To unload the patient, follow above instruction backwards.

 

Folded Down Position

Folded Up Position

Folded Up Position

 

 

Содержание BestMove STA400

Страница 1: ...R A I D M o d e l S T A 4 0 0 S T A 4 5 0 Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and prop...

Страница 2: ...h BestMove STA400 Max Load 400lb 182kg S N STA400YYMM1XXX 2920 Pacific Dr Norcross GA 30071 1 678 679 6690 Mass of Lift 60lb 27kg To better serve you please record the following information for future...

Страница 3: ...to form a secure and comfortable seat for the user to sit on for the remainder of the transfer The STA450 has a opening base to work with wide range of wheelchairs and furnitures The STA400 and STA450...

Страница 4: ...physical contact with the patient in order for the device to carry out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that...

Страница 5: ...kers discretion i e patients who are comatose spastic agitated or otherwise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toi...

Страница 6: ...dients to which patients are exposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Usi...

Страница 7: ...IVE NORCROSS GA 30071 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION...

Страница 8: ...0 mm 26 5 674 mm C Base Int Width Opened N A 31 8 808 3 mm D Lift Overall Height 43 3 1099 mm 43 3 1099 mm E Front Caster Height 4 7 119 mm 4 7 119 mm F Seat Pad Height 33 9 861 mm 33 9 861 mm G Knee...

Страница 9: ...rms Align the holes on each ends of handle bar with the holes on the arm and secure the handle bars to the arms using screws as follows Step 2 Connect the two mast to the left and right arms align the...

Страница 10: ...p 4 Insert the two kneepads into the kneepad crossbeam and secure the kneepad with hex bolts split washers washers Cover the bolt head with plastic cover Step 5 Insert the kneepad crossbeam to the mas...

Страница 11: ...e patient with optimal safety Never interfere with the lift unless instructed by the attendant Have a doctor nurse or medical attendant experienced in the use of the BestMove present during the first...

Страница 12: ...Have the patient grasp the cross bar closest to them and using their own strength pull themselves up into a standing position on the footplate platform If the patient needs assistance pulling themselv...

Страница 13: ...ok one of the hooking loops to the hook on the arm 4 Pull on the other hooking loop to assist the patient to stand up 5 Once the patient is seated on the seat pad hook the other hooking loop onto the...

Страница 14: ...isual inspection prior to use for the additional points below V The periodic inspection interval and the visual inspection points are listed below Note Bestcare assumes that the assembly instructions...

Страница 15: ...suance of a return authorization will also be refused as the authorization will have expired The final disposition of warranty claims will be subject to our inspection of the returned items Bestcare L...

Страница 16: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2021 09 www bestcarellc com 2021 Bestcare LLC...

Отзывы: