Bestcare BESTLIFT PL400EF Скачать руководство пользователя страница 27

26

WARRANTY POLICY

Bestcare offers a limited warranty on all patient lifts, slings and accessories to be free of defects in workmanship and product 

performance. This warranty extends only to the original purchaser and is non-transferable. All warranty claims must be submitted by 

the authorized dealer or distributor who originally sold the product with proper proof of sale and serial number where applicable. Prior 

Return Authorization (RA) from Bestcare is required for all warranty replacements. Bestcare reserves the right to repair or replace only 

defective parts or accessories in lieu of a complete new patient lift. The repaired or replacement part shall be warranted for a period 

equal to the remainder of the warranty period of the defective part.

Bestcare does not provide advance replacements for warranty claims.  For situations where an end user requires a replacement in 

advance and before a warranty item can be returned, dealer or distributor must purchase the replacement at full cost.  All freight charges 

for the replacement are the sole responsibility of the dealer or distributor. When end user returns warranty item and item proves to be 

defective, Bestcare will issue full credit for the replacement less freight charges.

Product returned without RA number clearly marked on the package or product returned later than 30 days after authorization will be 

refused and returned at sender’s expense. Final disposition of warranty claims will be determined at the sole discretion of Bestcare.  

Warranty claims will be denied for any of the following: product abuse or misuse, accidental or malicious damage, improper installation, 

product used with parts, components or accessories with quality or specifications incompatible with product, adulterated product, user 

neglect, failure to maintain and service product as specified in the owner’s manual or care tag, serial number removed or defaced, or 

normal wear and tear. 

Bestcare warrants the following products and components beginning from the purchase invoice date for the specified time period:

WARRANTY PERIOD

PRODUCT OR COMPONENT

Three (3) Years

Patient lift frame or spreader bar

Two (2) Years

Actuator, control box, pendant, charger, weigh scale, Stand Aids ( all components of STA400 & STA450), or 

casters excluding normal tread wear

One (1) Year

Battery or hydraulic pump

Six (6) Months

Reusable fabric slings

Bestcare Single Patient Specific slings are designed for limited use with one patient and may not be laundered. Bestcare will replace 

any disposable sling found to have a manufacturing defect. Normal wear and tear will not be covered under warranty.

This warranty expressly excludes wearable components including but not limited to foam parts and caster tread.  Furthermore, this 

warranty is void and null for product that has not been purchased or paid for in full.

RETURN GOODS POLICY

Patient lifts may not be returned unless the wrong lift is shipped in error by Bestcare or the lift is heavily damaged or defective out of the 

box.  For all other items, purchaser may request a RA for purchased goods within thirty (30) days of purchase invoice date.  All returns 

must be received by Bestcare no later than thirty (30) days after authorization or the RA will be voided. Return package must be clearly 

marked with the RA number or the package may be refused and returned at sender’s expense. Returns are subject to a minimum 

restocking fee of 15% or more depending on the condition of the returned item. Patient lifts are subject to a minimum restocking fee 

of 25% or more.  Please note that patient lifts being returned must be in the original carton with all parts, components and packing 

materials included. Failure to comply with this requirement will incur higher restocking fees or a rejection of the return. Slings, parts and 

accessories may only be returned if they have not been used. There are no exceptions to this provision.

All freight charges are the sole responsibility of purchaser when any of the following occurs:  (i) ordering error where an incorrect item is 

shipped in accordance with purchase order, (ii) an order is canceled while in transit or (iii) delivery is refused by customer. 

Bestcare reserves the right to issue credit amounts based on strict adherence to this policy.

Содержание BESTLIFT PL400EF

Страница 1: ...o l d a b l e P o r t a b l e Ensure the product has been assembled according to the instructions in this manual All operators should read and understood the instructions for safe and proper operation...

Страница 2: ...manufacturing date can be found on the serial number label that is located at the top of the mast The YY in the serial number is the manufactured year and the MM is the manufactured month MAX LOAD 40...

Страница 3: ...never have to be worried about your lift not being charged and ready for use The PL400EF is intended to be used with patients who are completely immobile or totally dependent on the patient lift for...

Страница 4: ...physical contact with the patient in order for the device to carry out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that...

Страница 5: ...wise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patient lift should not be used for transportin...

Страница 6: ...xposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Using accessories detachable part...

Страница 7: ...t 8 Standing Bracket 13 Emergency Lowering 4 Leg Opening Pedal 9 Emergency Stop Button Charger 0 6 lb 0 3 kg 5 Base 10 Control Unit 11 lb 5 kg Combined Weight 1 5 69 8lb 31 7 kg UNLESS OTHERWISE SPECI...

Страница 8: ...I L M mm in A 1841 2 72 5 B 1237 5 48 7 C 603 7 23 8 D 526 7 20 7 E 812 8 32 0 F 771 4 30 4 G 576 6 22 7 H 336 4 13 2 I 544 1 21 4 J 258 4 10 2 K 491 0 19 3 L 121 0 4 8 M 20 3 0 8 N 1198 8 47 2 O 657...

Страница 9: ...mm I Base Opened Turning Diameter 55 1384 9mm H Base Closed Turning Diameter 51 1306 5mm Unloaded Lift Weight 89 7 lb 40 8 kg Standard Features 6 Point Spreader Bar 4 Rear Caster with Brake 3 Front Ca...

Страница 10: ...g the mast Step 4 Lift the mast upright Lock the rear casters first then lift the mast upright by grabbing onto the handle bars Step 2 Secure the stand to the mast Make sure the tab on the standing br...

Страница 11: ...10 Step 5 Insert the pin to the bottom hole to secure the mast in upright position Step 6 Remove the pin that is securing the boom Step 7 Remove lower actuator pin...

Страница 12: ...ll the lower end of the actuator as follows It is critical to have the motor part of the actuator to face the same direction as the big arrow as follows Step 9 Install the upper end of actuator and re...

Страница 13: ...ND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BESTCARE LLC IS PROHIBITED 9 27...

Страница 14: ...rage or Transport Step 1 Spreader bar at lowest position Step 2 Folding the boom Step 3 Folding the mast Step 4 Standing position 1 1 2 2 3 3 Warning The lift may fall and cause bodily injury if it is...

Страница 15: ...one that serves the needs of the patient while providing the patient with optimal safety Never interfere with the lift unless instructed by the attendant Have a doctor nurse or medical attendant expe...

Страница 16: ...mproperly Keep long charger cord out of walkway where it poses a tripping hazard Have the charger port on the controller facing away from the wall for easy disconnection When removing the battery need...

Страница 17: ...ring charging the LCD Display Panel will show one of the four signs below The DC Charger must be connected The emergency stop button must be released The battery will not be charged if the emergency b...

Страница 18: ...17 LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel...

Страница 19: ...w the LCD Display Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery need...

Страница 20: ...ment with Head Support Polyester M L XL Liko Guldmann Replacement Polyester with PU Coating M L XL Liko Guldmann Replacement with Head Support Polyester with PU Coating M L XL Liko Guldmann Disposable...

Страница 21: ...1 Hook up F Point 2 Hook up E Insert F through E 8 Strap Sling A B G H C D E F Point 1 Hook up A C Point 2 Hook up B D Point 3 Hook up E Point 4 Hook up F Point 5 Hook up H Point 6 Hook up G Insert H...

Страница 22: ...d Transfer From Wheelchair to Bed 1 Grasp the sling at each corner of the U shape of the commode aperture 2 The sling should be fitted with the grab handles on the back section facing outward 3 Help t...

Страница 23: ...0 years or 20 000 cycles The expected lifetime of the electrical components are 3 years Contact Bestcare for any recycling information First Received Monthly Every 3 Months Check connections between b...

Страница 24: ...propyl alcohol For slings with rigid supports remove the plastic inserts before washing Look for an opening near the plastic inserts for removal Machine wash warm or cold Do not wash with other colors...

Страница 25: ...g on usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside t...

Страница 26: ...he user The Emergency Lowering Device is located at the top of the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair The dev...

Страница 27: ...e date for the specified time period WARRANTY PERIOD PRODUCT OR COMPONENT Three 3 Years Patient lift frame or spreader bar Two 2 Years Actuator control box pendant charger weigh scale Stand Aids all c...

Страница 28: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2021 09 www bestcarellc com 2021 Bestcare LLC...

Отзывы: