- 10 -
FRAMING BEHIND CROSS
SUPPORT
INSTALL MOUNTING
BRACKET
1. Construct wood wall
framing
that is flush
with interior surface of wall studs.
Make sure:
a) the framing is centered over
installation location.
b) the height of the framing will allow the
mounting bracket
to be secured to
the framing within the dimensions
shown.
2. After wall surface is finished, secure
mounting bracket to framing with (2) 4.8 x
38mm mounting screws. See chart below
for mounting bracket location.
WOOD CROSS
SUPPORT BEHIND
DRYWALL
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a)
15-1/2”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
44”
44”
CEILING HEIGHT
8-FOOT
9-FOOT
9-1/2”
10-1/2”
11-1/2”
12-1/2”
13-1/2”
14-1/2”
38”
39”
40”
41”
10- FOOT (see note b)
41”
39”
40”
41”
42”
43”
42”
43”
38”
Notes:
a. Distance above cook top must not be less than 9-1/2”.
A maximun of 15-1/2” is highly recommended for best capture of cooking
impurities.
Distances iover 15-1/2” above the cook top are at the installers discretion-
providing that ceiling height and flue lenght permit.
b. Requires optional 10-foot flue extension, ducted model AEWC23SB or
AEWC23CB.
DRYWALL
FIG. 8