10
INSTALLING THE ANTI
‐
TIP STABILlTY
DEVICE
The anti
‐
tip bracket shipped with the range must
be properly secured to the rear wall as shown in
the pircture below.
The height of the bracket from the floor must be
determined after the range legs have been
adjusted to the desired height and after the
range has been leveled.
Measure the distance from the floor to the
bottom of the anti
‐
tip bracket receptacle on the
back of the appliance.
Position the two anti
‐
tip brackets on the wall at
the desired height plus 1/8" (0.32 cm). The
brackets must be placed at 2”5/16 (6,0 cm) from
the side of the range. The distance between the
two bracket is 31”1/4 (79.3 cm).
Secure the brackets to the wall with appropriate
hardware.
Slide the range against the wall until the brackets
are fully inserted into their receptacles on the
back of the range.
INSTALLATION
REQUIREMENTS
ELECTRICAL
A properly
‐
grounded horizontally
‐
mounted
electrical receptacle should be installed no higher
than 3" (7.6 cm) above the floor, no less than 2”
(5 cm) and no more than 8” (20,3 cm) from the
right side (facing product).
Check all local code requirements.
GAS
An agency
‐
approved, properly
‐
sized manual shut
‐
off valve should be installed no higher than 3"
(7.6 cm) above the floor and no less than 2” (5
cm) and no more than 8” (20.3 cm) from the left
side (facing product).
To connect gas between shut
‐
off valve and
regulator, use agency
‐
approved, properly sized
flexible or rigid pipe. Check all local code
requirements.