background image

36

bertazzoni.com

INSTALLATION

All Bertazzoni columns can be installed in a standard 635mm 
(25”) depth cutout. 
Finish the edges of the opening because they may be visible 
when the door is open.
For a built-in installation, to cover gaps between the appliance 
and the adjacent cabinets, special side profiles are factory-
installed and covering frames are provided with the product.
For panel ready columns, do not exceed the maximum 
weight of 34 kg (75 pounds) for door panel. Panel can have 
thickness ranging between 19mm (¾”) and 28mm (1 1/8”).

For instructions of product combinations please see the 

Multiple Installation Section (page 58).

CABINET REQUIREMENT

Installation of the appliance must be performed in accordance 
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the 
front facing of the wall or cabinet before you perform the 
installation.
The floor must be flat and must be capable of supporting the 
weight of the appliance when in use.

ELECTRICAL REQUIREMENT

The installation must comply with all applicable electrical codes. 
A properly - grounded horizontally - mounted electrical 
receptacle should be installed.
Place the electrical supply flush with the back wall and within 
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet 
depth.

TOP VIEW

FRONT VIEW 

E W

E W

W

E

E W

E W

W

E

5"

127

A separate circuit breaker servicing only this appliance is 
recommended.

PLUMBING REQUIREMENTS

Bertazzoni Freezer Columns are provided with a water filter 
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water 
supply system.
To connect to water supply system (for appliances equipped 
with ice maker) a 6,4mm (¼”) waterline with accessible 
shut-off valve must be supplied.
The solenoid connection on the appliance is 19mm (¾”) 
diameter but is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI 
(between 0.5 bar and 5 bar). Different pressures can cause 
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please 
see Use and Maintenance Manual.

BUILT-IN FREEZER COLUMNS

60cm (24”) Freezer Column Panel Ready

Installation requirements

Required floor support

450 kg  (992 lb)

For detailed installation specifications consult the multiple installation 
requirements page or each single product installation manual.

Dimensions in parentheses are millimeters unless otherwise 
specified.

Electrical supply

220-240 V 50/60 Hz 275 W 1,5 Amp

Service

10 Amp dedicated circuit

Power Connection

2-pole 220V SCHUKO plug with 
2m power cord