The hob can be installed by itself, in an isolated position or inserted between two kitchen units or between one kitchen unit 
and a wall. Furthermore the back wall and surrounding surfaces must resist a temperature of 65 K. 
To prevent the plastic layer which covers the kitchen unit from ungluing, the glue used to join the two surfaces together must 
resist temperatures of up to 150 °C 
The installation of the appliance must be carried out according to the norms in force of the country concerned and the 
appliance must be installed in a well ventilated place.  
This appliance is not equipped with devices to remove the products of combustion. The appliance must therefore be 
connected following  the norms for installation mentioned above. Special attention must be paid to the information below 
regarding aeration and ventilation of the premises.  

 

VENTILATION OF THE PREMISES 

To guarantee that the appliance works correctly it is necessary that the place where the appliance is installed is continuously ventilated. 

The volume of the premises must not be less than 25 m³   and the quantity of air needed must be based on the regular combustion  of 

gas and on the ventilation of the premises.  The natural flow of air w ill take place through permanent openings made in the  wall of the 

premises to be ventilated: these openings will be connected to the outside and must have a minimum section of 100 cm² ( see Fig. 2 ). 

These openings must be made in such a way that they cannot be obstructed.  

 

POSITION AND VENTILATION 

The cooking appliances that use  gas must always remove the products of combus tion via a hood linked to chimney s, chimney flues or 

via a direct connection to the outside ( see  Fig. 3 ). If it is not possible to fit  a hood it is possible to use a  fan, fitted on the window or 

facing  directly  outside, w hich  operates  when  the  appliance is in use. ( see Fig. 4 ). In

  this w ay  the norms in force of the cou ntry 

concerned regarding the ventilation of premises are strictly followed.  

 

BACKGUARD INSTALLATION INSTRUCTION 

1)  Remove n°2 screws fixing worktop as shown in fig.5 

2)  Place front part of the backguard and attach it from bottom side with the two removed screws (point 2) as shown in fig .6 

3)  Fix the front part of the backguard with the screws supplied with the backguard kit (fig.7) 

4)  Assemble back part with front part of the backguard and fix them with a screws supplied with the backguard kit (fig.8)  

 
 

CONNECTING THE APPLIANCE TO THE GAS SUPPLY 

Before connecting the appliance to the gas supply you first need to remove the plastic protective plug for the gas supply which 
is inserted under pressure in the gas inlet connection. To remove the plug simply unscrew it.  
Then make sure that the details shown on the label on the lower part of the case are compatible  with those of the gas supply.  
A label on the last page of this manual and on the lower part of the case  indicates the conditions for regulating the appliance: 
type of gas and pressure used. 
IMPORTANT: This appliance must be installed in accordance with the norms in force of the country concerned and it must only 
be used in a well-ventilated place.  
ATTENTION: Remember that the gas inlet connection for the appliance is  threaded 1/2 gas cylindrical male in accordance with 
the norms UNI-ISO 228-1. (Fig. 10) 

 

ADAPTING TO DIFFERENT TYPES OF GAS 

Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply.  
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 

To change the nozzles of the burners  use the following procedure: 

 

Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the nozzles with those designed 

for the new gas supply according to the information given in TABLE N° 2 shown below.

 

ATTENTION: After carrying out the changes described above, the technician must put the label corresponding to the new gas 
supply on the appliance to take the place of the old label. This label is found in the bag containing spare nozzles.  

 

TABLE N°2: Adapting to different types of gas   

 

 

APPLIANCE CATEGORY:   II2H3+  

Burner 

Types of Gas 

Pressure 

Nozzle 

Diameter 

Rater Capacity 

Reduced 

Capacity 

by-pass 

Diameter 

 

 

mbar 

1/100 mm. 

g/h 

l/h 

kw 

kcal/h 

kw 

kcal/h 

1/100 mm. 

 

Natural   G20 

20 

77 

95 

860 

0,48 

413 

34 reg. 

Auxiliary 

Butane   G30 

30 

50 

73 

860 

0,48 

413 

34 

 

Propane G31 

37 

50 

71 

860 

0,48 

413 

34 

 

Natural   G20 

20 

101 

167 

1,75 

1505 

0,6 

516 

36 reg. 

Semi-Rapid  Butane   G30 

30 

66 

127 

1,75 

1505 

0,6 

516 

36 

 

Propane G31 

37 

66 

125 

1,75 

1505 

0,6 

516 

36 

 

Natural   G20 

20 

129 

286 

2580 

1,05 

903 

52 reg. 

Rapid  

Butane   G30 

30 

87 

218 

2580 

1,05 

903 

52 

 

Propane G31 

37 

87 

214 

2580 

1,05 

903 

52 

Dual 

Natural   G20 

20 

70 

76 

0,8 

688 

0,48 

413 

34 reg. 

Inner 

Butane   G30 

30 

46 

58 

0,8 

688 

0,48 

413 

34 

 

Propane G31 

37 

46 

57 

0,8 

688 

0,48 

413 

34 

Dual 

Natural   G20 

20 

2x110 

419 

4,4 

3784 

1,8 

1548 

65 reg. 

Outer 

Butane   G30 

30 

2x69 

298 

4,1 

3526 

1,8 

1548 

65 

 

Propane G31 

37 

2x69 

293 

4,1 

3526 

1,8 

1548 

65 

 

 
 
 

REGULATION OF BURNERS: 

1) Regulation of the "MINIMUM" on the burners 

Содержание CB486G00X

Страница 1: ... GB INSTRUCTIONS FOR THE INSTALLATION MAINTENANCE pag 7 AND USE OF FIXED HOBS 48 1216 mm W x 25 1 8 640mm D ...

Страница 2: ... HOUSEHOLDS This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE This guideline is the frame of a European wide validity of return and recycling on Waste Electrical and Electronic Equipment TECHNICAL MANUAL FOR THE INSTALLER INFORMATION FOR THE INSTALLER The installation all regulations changes and maintenance referred to in this...

Страница 3: ... the backguard kit fig 8 CONNECTING THE APPLIANCE TO THE GAS SUPPLY Before connecting the appliance to the gas supply you first need to remove the plastic protective plug for the gas supply which is inserted under pressure in the gas inlet connection To remove the plug simply unscrew it Then make sure that the details shown on the label on the lower part of the case are compatible with those of th...

Страница 4: ... the electricity supply The switch must be of a suitable charge for the appliance with a minimum opening between the contacts of 3 mm Remember that the earth wire must not be interrupted by the switch Alternatively the electrical connection can also be protected by a differential switch of high sensitivity You are strongly advised to fix the special yellow green earth wire to an efficient earthing...

Страница 5: ...ise direction so that the knob is at MAXIMUM this corresponds to a large flame and then use one of the lighting dev ices described above When the burner is lit keep the knob pressed in for about 10 seconds in order to allow the flame to heat up th e thermocouple If the burner goes out when letting the knob go repeat the operation all over again N B You are advised not to try and light a burner if ...

Страница 6: ...NING THE APPLIANCE Never use abrasive cleaners Before cleaning the appliance it should be disconnected from the power supply Cleaning the work surface periodically clean the burner heads the cast iron pan supports and the bur ner caps using warm water Any spillage must always be removed as soon as possible using a rag If it become difficult to open or close a valve do not force it but immediately ...

Страница 7: ...7 ATTENTION for further details about cleaning of the appliance please contact your applliance retailer Fig 1 Fig 2 Fig 3 Fig 4 ...

Страница 8: ...8 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 ...

Страница 9: ...9 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...12 310779 ...

Отзывы: