BEROTEC GmbH
P a g e
|
13
MOFESSOR
Manual
6.
Troubleshooting
problem
possible reason
action
no oil on the chain
- tank empty
- nozzle blocked
- kinked hose
- nozzle misadjusted
- electric connections not
properly connected
→ refill oil
→ clean nozzle
→ check hose
→ check nozzle position
→ check connections
soiled rear wheel
- rain-mode not deactivated
after rain
- oil flow misadjusted
→ put rain-mode switch in
field of view
→ reduce oil flow
oil is leaking even
though ignition is turned
off
- control voltage cable is
connected to permanent
+12V
- hose damaged
→ see chapter 4.5
→ check hose
red LED isn’t working or
turning off by itself
- electric connections not
properly connected
- control voltage cable not
properly connected
→ check connections
→ see chapter 4.5
red LED is flickering
- rain-mode switch cable is
located too close to parts of
the ignition system
→ re-lay cable
red LED is permanently
on
- control voltage too low
→ check 12 V on control
voltage cable (black/white)
dosing valve doesn’t
work
- fuse broken
- connection failure
→ check fuse / fuse holder
→ check valve connection
7.
Disposal
Nonfunctional systems
shouldn’t be disposed as a whole but as individual parts
depending on the material. Non-recyclable parts have to be disposed according
to their type.