Page 7 von 23
26.08.2014
Ver. 1.9
Copyright Berner Kochsysteme 2015
Function conditions
-
maximum tolerance of the nominal voltage
+5%/-10%
-
frequency
50 / 60 Hz
-
IP CODE (Protection class in delivery state)
IP 11
Installation
Electrical data of the units
Unit performance ( 7,5 kW - BFEM20, BFEE20 )
3-phase (Voltage 400V/3~/N/PE +5% / -10%)
Connection
Colour
Frequency
Fuse
Phase
brown, black, grey
or 1,2,3
50 Hz / 60 Hz
B6 (F1)
T1A (F2)
N
blue
or 4
PE
yellow/green
Unit performance ( 12,0 kW - BFEM30, BFEE30 )
3-phase (Voltage 400V/3~/N/PE +5% / -10%)
Connection
Colour
Frequency
Fuse
Phase
brown, black, grey
or 1,2,3
50 Hz / 60 Hz
B6 (F1)
T1A (F2)
N
blue
or 4
PE
yellow/green
Unit performance ( 16,5 kW – BFEM40, BFEE40 )
3-phase (Voltage 400V/3~/N/PE +5% / -10%)
Connection
Colour
Frequency
Fuse
Phase
brown, black, grey
or 1,2,3
50 Hz / 60 Hz
B6 (F1)
T1A (F2)
N
blue
or 4
PE
yellow/green
Unit performance ( 15,0 kW – BFEM40/2, BFEE40/2 )
3-phase (Voltage 400V/3~/N/PE +5% / -10%)
Connection
Colour
Frequency
Fuse
Phase
brown, black, grey
or 1,2,3
50 Hz / 60 Hz
B6 (F1)
T1A (F2)
N
blue
or 4
PE
yellow/green
Unit performance ( 19,5 kW – BFEM50/2, BFEE50/2 )
3-phase (Voltage 400V/3~/N/PE +5% / -10%)
Connection
Colour
Frequency
Fuse
Phase
brown, black, grey
or 1,2,3
50 Hz / 60 Hz
B6 (F1)
T1A (F2)
N
blue
or 4
PE
yellow/green
Unit performance ( 24,0 kW – BFEM60/2, BFEE60/2 )
3-phase (Voltage 400V/3~/N/PE +5% / -10%)
Connection
Colour
Frequency
Fuse
Phase
brown, black, grey
or 1,2,3
50 Hz / 60 Hz
B6 (F1)
T1A (F2)
N
blue
or 4
PE
yellow/green
Optional Filter System ( 0,12 kW –
BEPSF1, BEPSF2 )
1-phase (Voltage 230V/1~/N/PE +5% / -10%)
Connection
Colour
Frequency
Fuse
Phase
brown, black, grey
or 1
50 Hz / 60 Hz
-
N
blue
or 2
PE
yellow/green