![Berner AHC10-1036 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/berner/ahc10-1036/ahc10-1036_important-instructions-manual_2738021003.webp)
-3-
TABLE 1 - Weight Chart
III. WALL PREPARATION
1. Position and center the mounting plate over the door
opening. The mounting plate must be positioned with the
45° lip and the rubber vibration gasket on top. Drill mount-
ing holes on the mounting plate.
See Figure 4.
2. Mark the wall in the center of each mounting plate hole.
The wall must provide sufficient support for the Air curtain.
The mounting hardware (supplied by others) must be
capable of supporting a minimum of three times the net
weight of the Air curtain.
See Weight Chart, Table 1.
If
the location of the marks on the wall do not provide suit-
able support, mark and drill additional holes.
3. Drill the four holes as marked on the wall and attach the
mounting plate with anchors (if used) and the four mount-
ing screws (provided by others).
Figure 4
Figure 5
Table 2
MOTOR DATA
Model
#Motors
@HP
120 V
1ø
208/240 V
1ø
460 V*
1 ø
Motor
Amps
Motor
Amps
Motor
Amps
AHC10-1036
1@½
7.2
4.0
1.3
AHC10-1042
1@½
7.2
4.0
1.3
AHC10-1048
1@½
7.2
4.0
1.3
AHC10-2048
2@½
14.4
8.0
2.6
AHC10-2060
2@½
14.4
8.0
2.6
AHC10-2072
2@½
14.4
8.0
2.6
AHC10-2084
2@½
14.4
8.0
2.6
AHC10-2096
2@½
14.4
8.0
2.6
AHC10-3096
3@½
21.6
12.0
3.9
AHC10-3108
3@½
21.6
12.0
3.9
AHC10-3120
3@½
21.6
12.0
3.9
*Special 1/3 hp Two Speed Motor
1"
Doorway Opening
Recommended Mounting
Plate Holes
45º Lip and Rubber
Vibration Gasket
2 Locking Screws
(One In Each Corner)
Mounting
Plate
45˚ Lip and Rubber
Vibration Gasket
Discharge
Nozzle
IV. ATTACHING THE AIR CURTAIN TO THE
MOUNTING PLATE
1. Raise the unit over the door (air discharge nozzle facing
down) and on to the mounting plate. First, tilt the unit up-
ward matching the top recessed edge of the unit to the top
45° angled lip on the mounting plate.
See Figure 5.
2. Lower the unit into place, allowing it to rest on the lower lip
of the mounting plate.
3. After the unit is securely attached to the mounting plate, re-
install the two (2) locking screws at the bottom corners.
See Figure 5.
WEIGHT IN POUNDS
Model
Unheated Electric Steam/Hot Water
AHC10-1036
65
71
98
AHC10-1042
68
74
104
AHC10-1048
70
76
109
AHC10-2048
95
107
134
AHC10-2060
125
137
171
AHC10-2072
130
142
181
AHC10-2084
140
152
197
AHC10-2096
145
157
208
AHC10-3096
165
183
228
AHC10-3108
170
188
240
AHC10-3120
175
193
248