background image

Battery replacement

If the icon “         ” appears on the LCD display, it indicates that the battery 
should be replaced. Open the battery case and replace the exhausted batte-
ry with new battery.

Waste disposal

This product has been manufactured using highgrade materials and com-
ponents which can be recycled and reused.

 

Never dispose of empty batteries and rechargeable batteries 

 

in household waste. As a consumer, you are legally required  

 

to take them to your retail store or to an appropriate collec 

 

tion site depending on national or local regulations in order  

 

to protect the environment.

 

The symbols for the heavy metals contained are:

 

Cd=cadmium, Hg=mercury, Pb=lead

 

This instrument is labelled in accordance with the EUWaste 

 

Electrical and Electronic Equipment Directive (WEEE). Please  

 

do not dispose of this instrument in household waste. The  

 

user is obligated to take end-of-life devices to a designated

 

collection point for the disposal of electrical and electronic    

 

equipment, in order to ensure environmentallycompatible

 disposal

 

This sign certifies that the product meets the requirements  

 

of the EEC directive and has been tested according to the    

 

specified test methods.

Technical changes, any errors and misprints reserved.

Содержание 213981

Страница 1: ...Bedienungsanleitung Artikelnummer 213981 Sprachen fr en de BERNER_Bedienungsanleitung__10145822_de pdf 2016 09 24...

Страница 2: ...Bedienungsanleitung Operating instructions Mode d emploi D GB F Feuchtigkeitsmesser Moisture Meter Humidim tre 213981...

Страница 3: ...eigt den Feuchtigkeitsgehalt der Materialien schnell an Eindringtiefe ca 20 40mm Batterieentladungsanzeige Automatische Abschaltung MAX MIN Funktion Mess und Haltefunktion LCD Anzeige mit wei er Hinte...

Страница 4: ...Beschreibung der Frontseite 1 2 3 4 5 6 7...

Страница 5: ...f dem LCD Display und zeigt somit an dass der aktuelle Messwert festgehalten wird MAX MIN Taste W hrend der Durchf hrung von Messungen dr cken Sie die MAX MIN Taste und das MAX Symbol erscheint auf de...

Страница 6: ...innen Dazu bet tigen Sie weiterhin dieTaste MEAS Halten Sie die Messsonde Kugel auf die zu messende Oberfl che Kugel und Messfl che sollten sich ber hren Immer senkrecht zur Oberfl che messen Randbere...

Страница 7: ...4 70 75 2 20 5 10 80 2 35 5 45 85 2 50 5 75 90 2 65 6 10 Die Angaben sind Cirka Angaben Je nach Hersteller k nnen die Angaben f r Baustoffe entsprechend abweichend Die Angaben f r Holz wurden durch Br...

Страница 8: ...haltene Schwermetalle sind Cd Cadmium Hg Quecksilber Pb Blei Dieses Ger t ist entsprechend der EU Richtlinie ber die Entsorgung von Elektro und Elektronik Altger ten WEEE gekennzeichnet Dieses Produkt...

Страница 9: ...ings and floors It is particularly suitable for pre testing the readi ness of building materials for covering prior to CM measurement Features Quickly indicate the moisture content of materials Depth...

Страница 10: ...vicinity of older equipment or equipment equally sensitive to high frequencies e g functioning medicinal equipment Use the instrument only for measuring the dampness in harde ned building materials by...

Страница 11: ...Front Panel Description 1 2 3 4 5 6 7...

Страница 12: ...button the HOLD icon will appear on the LCD indicating that the current reading is being held MAX MIN Button When taking measurements press MAX MIN Button the MAX icon will appear on LCD display and t...

Страница 13: ...isappears Now you can start with the measurements Hold the instru ment as near to the back as possible Press the MEAS button and use the ball to scan the surface under investigation The ball must be i...

Страница 14: ...25 12 00 30 0 25 15 00 35 0 30 2 50 17 00 40 0 40 2 65 20 00 45 0 65 2 85 50 1 00 3 20 55 1 40 3 55 60 1 70 4 00 65 1 90 4 30 70 2 05 4 70 75 2 20 5 10 80 2 35 5 45 85 2 50 5 75 90 2 65 6 10 This inf...

Страница 15: ...ured has a noticeable affect Basically the value displayed with dry and damp building materials increases correspondingly with increasing raw density The values given in the table below are indicative...

Страница 16: ...ng on national or local regulations in order to protect the environment The symbols for the heavy metals contained are Cd cadmium Hg mercury Pb lead This instrument is labelled in accordance with the...

Страница 17: ...rapidement la teneur en humidit des mat riaux Profondeur de p n tration env 20 40 mm Indicateur de d charge de batterie Arr t automatique Fonction MAX MIN Fonction de mesure et de maintien Ecran LCD a...

Страница 18: ...Description de la face avant 1 2 3 4 5 6 7...

Страница 19: ...e d affichage HOLD appara t sur l cran LCD et la valeur de mesure actuelle reste fig e l cran Touche MAX MIN Pendant l ex cution des mesures appuyez sur la touche MAX MIN L ic ne MAX appara t alors su...

Страница 20: ...surer perpendiculairement la surface et viter les bordures angles La pr sence de m tal dans les mat riaux de construction peut entra ner des mesures inexactes Les informations suivantes sont donn es t...

Страница 21: ...2 20 5 10 80 2 35 5 45 85 2 50 5 75 90 2 65 6 10 Les donn es sont approximatives Les donn es concernant les mat riaux de construction peuvent diff rer selon le fabricant Celles concernant le bois ont...

Страница 22: ...tionale et locale Les m taux lourds sont d sign s comme suit Cd cadmium Hg mercure Pb plom Cet appareil est conforme aux normes de l UE relatives au traitement des d chets lectriques et lectroniques W...

Страница 23: ...RMITY Product name Pinless Humid Check Material number 213981 Description Check of humid at construction side Construction method complies with all essential requirements of the following directives E...

Страница 24: ......

Страница 25: ...153 44 05 14 F Irrt mer und technische nderungen vorbehalten Berner Trading Holding GmbH Bernerstra e 6 74653 K nzelsau Germany T 49 0 7940 121 0 F 49 0 7940 121 203 info berner group com...

Отзывы: