SECTION 6 — INSTALLATION
6-1 Installing Quick-Connect Block to Feeder
1. Insert the correct feeder adaptor liner for desired wire diameter
(2 provided) flush with the threaded end of the feeder adaptor.
2. Tighten set screw.
3. Thread feeder adaptor into quick-connect block and tighten.
4. Position assembly into feeder adaptor and trim liner within
1/16" (1.6 mm) of the drive rolls and remove burrs if
necessary.
5. Secure assembly into feeder.
6. Thread gas hose nipple into feeder gas fitting.
7. Connect power cable to 1/2" (13 mm) power bolt with
appropriate lug.
8. Tighten all connections.
9. Feed welding wire through assembly by hand and tighten drive
rolls.
Figure 6-A
Figure 6-B
12