Berkley Tool SSHM-2 Скачать руководство пользователя страница 2

Safety

2

READ AND FOLLOW

SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury:

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The label 

NOTICE 

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 

Replace missing or damaged safety labels.

ELECTRICAL SAFETY

Wire motor for correct

voltage. See “Electrical”

section of this manual and
motor nameplate.

Ground motor before

connecting to power 

supply.

Meet National Electrical

Code, Canadian Electri-

cal Code, and local codes for
all wiring.

Follow wiring instruc-

tions in this manual

when connecting motor to
power lines.

Make workshops childproof; use padlocks and master
switches; remove starter keys.

Do not touch an operating motor.

Modern

motors can operate at high temperatures. To avoid burns
when servicing pump, allow it to cool for 20 minutes
after shut-down before handling. 

GENERAL SAFETY

To avoid heat built-up in pump, over pressure hazard and
possible injury, do not use in a pressure tank (domestic
water) system. Do not use as a booster pump; pressurized
suction may cause pump body to explode.

Do not allow pump or piping system to freeze. Freezing
can damage pump and pipe, may lead to injury from
equipment failure and will void warranty.

Pump water only with this pump.

Periodically inspect pump and system components.

Wear safety glasses at all times when working on pumps.

Keep work area clean, uncluttered and properly lighted;
store properly all unused tools and equipment.

Keep visitors at a safe distance from the work areas.

Maximum inlet pressure .........................................30 psi

Maximum operating pressure ...............................130 psi

Maximum liquid temperature ................................120° F

Maximum motor starts per hour...................................15

WARNING

Hazardous pressure! 
Do not run pump against
closed discharge.

Release all pressure on 
system before working on 
any component.

WARNING

Hazardous voltage.
Can shock, burn, or
cause death.

Ground pump before 
connecting to power 
supply.

Содержание SSHM-2

Страница 1: ...L Self Priming Horizontal Multistage Pump Installation Operation Parts For further operating installation or maintenance assistance Call 1 888 237 5353 2007 BE682 Rev 12 3 08 SSHM 2 293 Wright St Dela...

Страница 2: ...power lines Make workshops childproof use padlocks and master switches remove starter keys Do not touch an operating motor Modern motors can operate at high temperatures To avoid burns when servicing...

Страница 3: ...erter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your...

Страница 4: ...g Leave room to use wrenches 8 Pump body may explode if used as a booster pump DO NOT use in a booster application NOTICE Use the installation method on page 5 which matches your well type 9 Install a...

Страница 5: ...ipe Flow arrow on check valve must point toward pump HORIZONTAL PIPING FROM WELL TO PUMP 1 Never install a suction pipe that is smaller than the suction port of the pump 2 To aid priming on well point...

Страница 6: ...electrical power supply Failure to ground motor can cause severe or fatal electrical shock hazard Do not ground to a gas supply line To avoid dangerous or fatal electrical shock turn OFF power to moto...

Страница 7: ...ated fittings 6 Protect current carrying and grounding conductors from cuts grease heat oil and chemicals 7 Connect current carrying conductors to terminals L1 and L2 under motor canopy single phase o...

Страница 8: ...ith water before starting 1 Remove priming plug Figure 13 2 Make sure suction and discharge valves and any hoses on discharge side of pump are open 3 Fill pump and suction pipe with water 4 Replace pr...

Страница 9: ...nnect the suction line 5 Remove four capscrews Key No 18 from the pump see Figure 17 6 Pull the pump suction body forward see Figure 18 Remove the sleeve Key No 9 by pulling it straight forward Be car...

Страница 10: ...dirt foreign particles scratches and grease 7 Inspect the shaft to be sure it is free of nicks and scratches PUMP REASSEMBLY 1 Bolt the bracket down to the foundation see Figure 23 2 Slide the motor...

Страница 11: ...ine and shaft seal 2 Water level below suction pipe inlet 2 Lower suction line into water and re prime If receding water level in well exceeds 20 6 1M a deep well pump is needed Foot valve or strainer...

Страница 12: ...Key Nos 6 8 and 10 14 6 Shaft Seal 1 U9 6 U9 6 7 Spacer 1 121P1710 121P1710 8 O Ring 2 111P2700 111P2700 9 Sleeve 1 251A4310 251A4310 10 Diffuser 4 101P4790 101P4790 11 Impeller 4 101P2070 101P2070 1...

Отзывы: