Berker RolloTec Скачать руководство пользователя страница 2

Product characteristics 

Serpentine-shaped sensor surface detects wetting due to precipitation. 

Change-over relay remains switched on until the sensor is dry again. For at least 10 
minutes. 

Integrated heater speeds up the drying of the sensor surface and melts snow and ice. 

4 Information for electrically skilled persons 

4.1 Fitting and electrical connection 

Fitting the device 

The 110° mounting bracket ensures an optimal mounting position at all times for mounting on 
vertical walls. The mounting bracket can be installed on a mast using the supplied clamp. 

Mount the precipitation sensor in such a way that rain can reach it in an unobstructed 
manner. 

Connecting the device 

DANGER! 
Electrical shock when live parts are touched. 
Electrical shocks can be fatal. 
Before working on the device, disconnect all the corresponding miniature 
circuit breakers. Cover up live parts in the working environment. 

Connected to the precipitation sensor are two PVC hose lines with numbered wires.
Control cable (4)
Wire 1: NC contact
Wire 2: centre contact
Wire 3: NO contact 

Figure 2: Example for connection of precipitation sensor to blind/shutter controller (6) 

Connect mains cable (3) and control cable (4) of the precipitation sensor (5) as shown in 
the connection example (Figure 2). Wire 3 of the control cable should be connected to the 
outer conductor so that no voltage is present on the free wire 1. 

The change-over contact can be used for either 230 V or for safety extra-low voltage. 

Seite 2/3 

10.05.2012 

82556711 
97-09589-000 