4
6T 7973-31a
O
C
O
M
11
36
57
3
6T 7973-31a
Other devices can be added to the installation.
Various configuration options are available
When a detector is associated with a receiver,
only 2 functions are available, depending on
potentiometer’s position :
Setting detector’s delay
Setting receiver’s delay
15 min
30 s
5 min
15 min
s
5 min
30
1 detector 8536 52 00
+
1 receiver
Recommended configuration :
1. Set the potentiometer to a value different
from
2. Configure ON/OFF switch function (see
configuration instructions
quick
link
&
)
1. Set the potentiometer to position
2. Configure the "timer"
(see configuration instructions
quick
link
&
)
1 detector 8536 52 00
+
several receivers
1. Set the potentiometer to a value different
from
2. Configure the ON/OFF switch function (see
configuration instructions
quick
link
&
)
on each receiver
In order to have a different delay on each receiver :
1. Set the potentiometer to position
2. Configure the "timer"
function
(see configuration instructions
quick
link
&
)
Several detectors
8536 52 00
+
1 or several
receivers
Not recommended (conflict of delays)
1. Set the potentiometer to position
on both
detectors.
2. Configure the "timer"
function
(see configuration instructions
quick
link
&
)
on each receiver
1 detector 8536 52 00
+
1 or several
transmitters
other than detectors
+
1 or several
receivers
Timer function being not used on the other
transmitter(s) :
1. Set the potentiometer to a value different
from
2. Configure the other transmitter(s)
(see configuration instructions
quick
link
&
)
with a function other than timer.
Timer function used on the other transmitters :
1. Set the potentiometer to position
2. Configure the "timer"
function
(see configuration instructions
quick
link
&
)
on each receiver for each transmitter involved
Note :
During configuration of a detector, Step 2 of the configuration instructions
quick
link
&
shall be ignored.
TROUBLESHOOTING...
P
ROBLEM
C
AUSES
S
OLUTIONS
Unwanted lamp
switch on.
- Permanent heat source is active in the detection area (trees, bushes
shook by wind or presence of dogs, cats in the detection area).
- The detector is located on top a ventilation grill.
- Limit detector’s range by adjusting its inclination or by fitting
shuttering blades to the lens, or by lowering sensitivity using the
adjustment knob.
- Move the detector to another location.
The range of
the detector is
too narrow.
- Detector’s installation height is not suitable (too high or too low).
- Sloppy ground.
- Modify installation height (2.5 m is optimal).
- Adjust detector’s direction.
Moving vehicle or
person is not
detected.
- Vehicle’s motor is not enough yet (heat radiation is too weak).
- People move forwards in front of detector.
- Detector energy too low.
- Install the detector in such a way that objects move within the area
in transverse direction.
- Place detector in a suitable location with solar cell directed
towards the sun.
Technical specifications
Electrical specifications
Power Supply :
Solar
Operational characteristics
Dimensions (L x w x h) : 153 x 91 x 130 mm
Luminosity threshold : 5 … 1000 Lux
Fixed time : 30 s … 15 min
Sensitivity : min. 20%, max. 100%
Limiting the detection zone : adjustable shutters
supplied
Transmission frequency : 868.3 MHz
Transmitter duty cycle : 1%
Receiver category : II
Range : 100 m on open field
Fixing accessories : corner support
(sold separately) Order no. 8590 02 00
Environment
Operating temperature : -20 … +55 °C
Storage temperature : -20 … +60 °C
IK : 04
Protection class : IP55
Resistance to fire : 750 °C
Standards
: EN 60950-1 ; EN 301489-3 ;
EN 300220-2 ; EN 50491-3
-
(Red/Green LED) or timer
(Red flashing LED)
according to the case
- Delete
(LED is OFF)
The receiver will offer only the function set by the
potentiometer.
When a product is factory reset,
pre-configuration is removed.
It should then be configured again.