Deleting radio transmitters
o
Teach-in again the radio transmitter to be deleted.
The red LED lights up to confirm that a radio transmitter has been deleted.
5 Appendix
The symbol confirms the conformity of the product to the relevant guidelines.
5.1 Technical data
Rated voltage
AC 230 V ~
Mains frequency
50 / 60 Hz
Ambient temperature
-20 ... +55 °C
Protection rating
IP 20 / IP 54
Connection cable
1.5 m
Dimensions W×H×D
110×94×38 mm
Teachable radio transmitter
max. 60
Carrier frequency
433.42 MHz (ASK)
Transmitting range in free field
typical 100 m
Transmitting power
< 10 mW
5.2 Troubleshooting
Radio receiver does not respond, or only sometimes.
Cause 1: Radio range exceeded. Structural obstacles reduce the range.
Check routing of antenna. Laying the antenna stretched out increases the range (see
chapter Routing the antenna out of the housing).
Cause 2: Incorrect switch setting
Prog
(11).
Turn
Prog
switch to the
OFF
position.
5.3 Warranty
We reserve the right to make technical and formal changes to the product in the interest of
technical progress.
Our products are under guarantee within the scope of the statutory provisions.
If you have a warranty claim, please contact the point of sale or ship the device postage free
with a description of the fault to the appropriate regional representative.
Berker GmbH & Co. KG
Klagebach 38
58579 Schalksmühle/Germany
T 49 (0) 2355/905-0
T 49 (0) 2355/905-111
www.berker.de
Seite 5/5
22.05.2012
82530511
97-09506-000
radio bus
Radio signal amplifier surface-mounted