Preparing to Start the Pump – Shallow Well

8

Never run pump against closed discharge. To do so can boil

water inside pump, causing hazardous pressure in unit, risk of explosion
and possibly scalding persons handling pump.

Never run pump dry. Running pump without water may cause

pump to overheat, damaging seal and possibly causing burns to persons
handling pump. Fill pump with water before starting.
Step 1. Open the control valve as far as possible (see Figure 12). Then

remove the priming plug from the pump and fill the pump, fill all
piping between the pump and the well, and make sure that all pip-
ing in the well is full. If you have also installed a priming tee 

in the

suction piping, remove the plug from the tee and fill the suction
piping.

Step 2. Replace all fill plugs. Leave the control valve open (in a shallow

well installation, the control valve always stays open).

Step 3. Power on! Start the pump. The pump should pump water in two or

three minutes.

Step 4. If you don’t have water after 2 or 3 minutes, stop the pump and

remove the fill plugs. Refill the pump and piping. You may have to
repeat this two or three times in order to get all the trapped air out
of the piping. The control valve remains open throughout this pro-
cedure.

Step 5. After the pump has built up pressure in the system and shut off,

check the pressure switch operation by opening a faucet or two and
running enough water out to bleed off pressure until the pump
starts. The pump should start when pressure drops to 30 PSI and
stop when pressure reaches 50 PSI. Run the pump through one or
two complete cycles to verify correct operation. This will also help
clean the system of dirt and scale dislodged during installation.

Open control valve
as far as possible
and fill pump and
piping through
priming port
or priming tee.

2411 0497

To Household
Water System

60

80

100

40

20

Figure 12: Open Control Valve

Содержание HL series

Страница 1: ...ation Operation Parts For further operating installation or maintenance assistance Call 1 800 363 PUMP 7867 PRINTED IN U S A BE423 Rev 3 18 98 20 40 60 80 100 2434 0497SR HL and SL Series 1800 Courtne...

Страница 2: ...ouch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump...

Страница 3: ...ing Berkeley Wicor dealer as soon as possible after the dis covery of any alleged defect Berkeley Wicor will subsequently take corrective action as promptly as reasonably possible No requests for serv...

Страница 4: ...0 60 80 10 0 Priming Tee and Plug Drive Coupling Drive Point Check Valve Drive point below water level Pressure Gauge Priming Tee and Plug Well Casing Foot Valve Sanitary Well Seal Suction Pipe From W...

Страница 5: ...f pass ing the entire pump capacity at 75 PSI pressure Connect the Air Volume Control AVC tube to the 1 8 NPT AVC port on the pump body Run the tubing from the pump s AVC port to the AVC mounted on th...

Страница 6: ...re 8 Figure 8 Motor wiring connections through Pressure Switch Match motor voltage to line voltage Your Motor Terminal Board under the motor end cover and Pressure Switch look like one of those shown...

Страница 7: ...11 and let the pressure drop until the pressure gauge needle starts to flutter When the needle flutters close the valve just enough to stop the flutter see Figure 11 Your pump is now operating at its...

Страница 8: ...alve open in a shallow well installation the control valve always stays open Step 3 Power on Start the pump The pump should pump water in two or three minutes Step 4 If you don t have water after 2 or...

Страница 9: ...t Key Part 5SL 7SL 10SL 15SL No Description Qty 1 2 HP 3 4 HP 1 HP 1 1 2 HP 1 Motor 1 A100CLL A100DLL A100ELL A100FLL 2 Water Slinger 1 C69 2 C69 2 C69 2 C69 2 3 Seal Plate 1 N3 9 N3 9 L3 10 L3 10 4 S...

Страница 10: ...shallow well pump installed on a well with more than 25 ft depth to water in this case a deep well jet pump is needed D Pump does not deliver water to full capacity D Possible causes are the well wat...

Отзывы: