Berkeley HL series Скачать руководство пользователя страница 1

OWNER’S MANUAL

Convertible Deep Well Jet Pumps

Installation/Operation/Parts

For further operating, installation, or maintenance assistance: 

Call 1-800-363-PUMP (7867)

PRINTED IN U.S.A.

BE423 (Rev. 3/18/98)

20

40

60

80

100

2434 0497SR

“HL” and “SL” Series

1800 Courtney Park Drive East, 
Unit 5-7, Mississauga, Ontario L5T 1W1

Содержание HL series

Страница 1: ...ation Operation Parts For further operating installation or maintenance assistance Call 1 800 363 PUMP 7867 PRINTED IN U S A BE423 Rev 3 18 98 20 40 60 80 100 2434 0497SR HL and SL Series 1800 Courtne...

Страница 2: ...ouch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump...

Страница 3: ...ing Berkeley Wicor dealer as soon as possible after the dis covery of any alleged defect Berkeley Wicor will subsequently take corrective action as promptly as reasonably possible No requests for serv...

Страница 4: ...0 60 80 10 0 Priming Tee and Plug Drive Coupling Drive Point Check Valve Drive point below water level Pressure Gauge Priming Tee and Plug Well Casing Foot Valve Sanitary Well Seal Suction Pipe From W...

Страница 5: ...f pass ing the entire pump capacity at 75 PSI pressure Connect the Air Volume Control AVC tube to the 1 8 NPT AVC port on the pump body Run the tubing from the pump s AVC port to the AVC mounted on th...

Страница 6: ...re 8 Figure 8 Motor wiring connections through Pressure Switch Match motor voltage to line voltage Your Motor Terminal Board under the motor end cover and Pressure Switch look like one of those shown...

Страница 7: ...11 and let the pressure drop until the pressure gauge needle starts to flutter When the needle flutters close the valve just enough to stop the flutter see Figure 11 Your pump is now operating at its...

Страница 8: ...alve open in a shallow well installation the control valve always stays open Step 3 Power on Start the pump The pump should pump water in two or three minutes Step 4 If you don t have water after 2 or...

Страница 9: ...t Key Part 5SL 7SL 10SL 15SL No Description Qty 1 2 HP 3 4 HP 1 HP 1 1 2 HP 1 Motor 1 A100CLL A100DLL A100ELL A100FLL 2 Water Slinger 1 C69 2 C69 2 C69 2 C69 2 3 Seal Plate 1 N3 9 N3 9 L3 10 L3 10 4 S...

Страница 10: ...shallow well pump installed on a well with more than 25 ft depth to water in this case a deep well jet pump is needed D Pump does not deliver water to full capacity D Possible causes are the well wat...