Berkeley 10PL Скачать руководство пользователя страница 11

11

Symptoms

Things to Do:

A. Motor will not run.

A. Check that the disconnect switch is ON and that the circuit breaker 

has not tripped or the fuse has not blown.
DISCONNECT POWER and make sure that wires connecting motor to
power supply and pressure switch are tight and correctly connected 
(see Page 7).
If the remedies above do not solve the problem, call your well 
professional.

B. Motor runs hot and overload trips.

B. Turn to electrical instructions on Page 7 and verify that motor is 

correctly wired.
Check with the power company or hydro authority to make sure 
that the voltage at the pump is  10% of the motor’s rated 
nameplate voltage. 
DISCONNECT POWER and make sure that the wires connecting the 
motor to the power supply are sized according to Wiring Chart, Page 7.
If not, rewire according to the instructions on Page 7.
If the pump is cycling too frequently, see Section E, below.

C. Motor runs but no water is delivered.

C. FIRST, check the prime; that is, make sure that the pump and all the 

suction piping plus the piping in the well are full of water. If they 
aren’t, fill them up.
In cold weather, make sure that the pipes and pump are not frozen. 
If they are, thaw them, watching out for split pipes and fittings as you
work. Heat the pump pit or pump house and bury all piping below 
the frost line.
Other possible causes (call your pump professional if you suspect one
of these): Air leaks in the suction line, dropping water level in the well,
foot valve stuck or plugged, ejector plugged, impeller plugged, foot 
valve or strainer stuck in the mud in the bottom of the well, a shallow 
well pump installed on a well with more than 25 ft depth to water 
(in this case a deep well jet pump is needed).

D. Pump does not deliver water to full capacity.

D. Possible causes are: the well water level is lower than estimated, 

making a different nozzle/venturi combination necessary; steel piping 
(if used) is corroded or limed, restricting capacity and increasing 
friction; or the piping is too small for the installation. Consult your 
well professional for any of these  conditions.

E. Pump cycles too frequently or does not shut 

E.  Make sure no faucets have been left open. 

off at all.

If system has a standard tank, make sure it isn’t waterlogged. If it is, 
drain it down to the level  of the air volume control. Make  sure the
AVC isn’t defective and that there are no leaks at any connections.
If system has a precharged tank, 

disconnect power

, open all system 

faucets and bleed all pressure off of tank. Use a tire gauge to check 
the air pressure in the tank. This should be lower than the cut-in setting 
of the pressure switch by 2 PSI (that is, if the pressure switch starts the 
pump at 30 PSI, the precharge should be 28 PSI). Check the air valve
for leaks (use a soap solution) and replace the core if necessary.
If you suspect any of the following conditions, consult your well 
professional: leaky pipes, leaky foot valve, water level in the well 
lower than  estimated, clogged ejector or impeller. 

F. Air spurts from faucets.

F.  Pump may still be priming; when priming is complete all air will have

been ejected from the system. 
If you suspect leaks in the suction piping, gasses in the well, or that the
pump is intermittently overpumping the well (that is, drawing the water
level down below the foot valve), consult your well professional.

G. Pump leaks around clamp.

G. Tighten clamp nut 1-2 turns. 

Do not overtighten.

TROUBLESHOOTING CHART

Содержание 10PL

Страница 1: ...els Electrical Safety Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank Capacitor voltage may be hazar...

Страница 2: ...0 5 8 3 0 16 2 15 8 15 3 8 7 1 3 10 8 2 8 0 7 8 5 2 2 3 14 2 14 0 13 8 7 2 15 7 2 6 8 6 8 4 5 1 8 12 2 12 0 11 8 5 3 20 5 7 5 7 5 7 3 8 9 7 9 7 9 2 3 7 25 4 3 4 3 4 3 3 2 7 2 6 8 6 8 Model 3PL Model 5...

Страница 3: ...8 14 4 10 6 6 4 18 6 15 6 12 3 8 7 40 9 2 11 0 7 4 4 7 15 25 12 4 9 2 6 0 50 8 5 6 0 3 7 1 6 12 3 9 0 6 4 3 2 GPM with J32P 18 Venturi and 52 Nozzle GPM with J32P 29 Venturi and 54 Nozzle 60 5 5 3 75...

Страница 4: ...he plumbing connections do not put a strain on the pump body Support the pipe so that the pump body does not take the weight of piping or fittings SHALLOW WELL Hazardous voltage Disconnect power to pu...

Страница 5: ...ld sepa rately Follow the instructions provided with the kit Align the venturi with the top hole on the front of the pump See Figure 3 2 Mount the pump as close to the well as possible 3 Assemble the...

Страница 6: ...Well Figure 8 1 Assemble Berkeley ejector kit BK4800 sold separately Follow the instructions included with the kit in order to match the nozzle and venturi to your well conditions 2 Mount the pump as...

Страница 7: ...rge tee to your plumbing system 4 Check the pre charge of air in the tank with an ordinary tire gauge The pre charge should be 2 psi less than the cut in setting of the pump s pressure switch The pre...

Страница 8: ...ground screw under the motor end cover Use a solid copper wire at least as large as the power supply wires 3 Connect the ground wire to a grounded lead in a service panel to a metal underground water...

Страница 9: ...get all the trapped air out of the piping Don t forget to close the control valve each time before you start the pump 5 When pressure has built up and stabilized at about 50 psi slowly open the contr...

Страница 10: ...sure that all piping in the well is full If you have also installed a priming tee in the suction piping remove the plug from the tee and fill the suction piping 2 Replace all fill plugs Leave the con...

Страница 11: ...ed on a well with more than 25 ft depth to water in this case a deep well jet pump is needed D Pump does not deliver water to full capacity D Possible causes are the well water level is lower than est...

Страница 12: ...9 199 U9 199 U9 199 U9 199 U9 199 U9 199 12 Pump body clamp 1 C19 54SS C19 54SS C19 54SS C19 54SS C19 54SS C19 54SS 13 Pump body front half 1 L76 37P L76 37P L76 37P L76 37P L76 37P L76 37P 14 Control...

Страница 13: ...as possible after the discovery of any alleged defect Berkeley Wicor will subsequently take cor rective action as promptly as reasonably possible No requests for service under this warranty will be a...

Отзывы: