INTERLOCK CABLES / INDEX
KNOB ADJUSTMENTS
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1.
Insert cable into index knob.
A.
Disconnect clevis pin and remove clevis
from interlock slide bar.
Fig. 64
B.
Remove INDEX KNOB.
C.
Push cable until it stops.
D.
Adjust gauge plate to knife height as
outlined under GAUGE PLATE
ADJUSTMENT.
E.
Replace INDEX KNOB.
NOTE:
Make sure end of cable goes into index knob
hole within spiral groove.
Fig. 65
F.
Torque nut to 140 in.-lbs.
2.
Attach cable to slide rod.
A.
Install product table as outlined under
PRODUCT TABLE.
B.
Pull clevis to retract cable from index knob
until index knob turns freely.
C.
Open index knob 1/4 turn and push cable in
as far as it will go.
D.
Turn clevis until hole aligns with hole in
interlock slide rod.
E.
Turn clevis CW one full revolution.
F.
Attach clevis to interlock slide rod with clevis
pin.
GAUGE PLATE ADJUSTMENT
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
The slicer knife is very sharp. Exercise extreme
caution when working near the knife.
1.
Gauge plate to knife gap.
A.
Pull rubber boot away from adjustment
block.
B.
Loosen bolts and slide gauge plate into
position.
Fig. 66
NOTE:
Gauge plate to knife gap should be 1/8" at
center of gauge plate. As knife wears, gap at top and
X13 SLICER - SERVICE PROCEDURES AND ADJUSTMENTS
Page 25 of 36
F25332 Rev. A (0718)