JOG function: JOG Mode and motorpotentiometer
TAB1
If the JOG is enabled the output frequency may be controlled by the keyboard (INC
and DEC buttons).
The frequency control in the JOG Mode is possible after the enable operation is done
and by returning to TAB1, function 1.
The JOG Mode enable operation is signaled by the alternate visualization of the para-
meter value and of the "JOG" message. The impased value in TAB1, function 1 isn’t
savable.
When the JOG function is disabled, the inverter returns to the output frequency
determined by the speed reference signal or by an eventually preset frequency.
With the "motorpotentiometer" function enabled (JOG MPt), the frequency control is
made by terminal 25 (increase frequency) and terminal 26 (decrease frequency).
MPt1:
the impased frequency isn’t saved.
MPt2:
the impased frequency is automatically saved after 2.5 seconds. After a
restart the inverter returns to this frequency.
Enabling a preset frequency, this frequency is acquired by the motorpotentiometer
even if the frequency is in the skip-band frequencies or is out of range f
max
or f
min
.
In the first case the inverter returns to the higher or the lower frequency of the skip-
band in function of the input direction in the skip-band and immediatly after the preset
frequency is disabled. In the second case the output frequency returns to f
max
or f
min
immediatly after the motorpotentiometer function is disabled.
Functioning modes:
a)
Frequency control by the motorpotentiometer and control of the rotation sense by
the REVERSING input terminal 15
(TAB2, SUBREF, function REF = 1, 3, 4 or 5)
If the rotation sense doesn’t corrispond to the sense of the motor, the output
frequency remains the same and the inverter signals "MPtFault".
b)
Frequency and rotation sense control by the motorpotentiometer
(TAB2, SUBREF, function REF = 2)
Range: ON, OFF
MPt1, MPt2
Default: OFF
Motorpotentiometer
function
available only
with software
D2A-STD
JOG OFF
Term. 25
Term. 26
Rotation sense
Reaction
OFF
OFF
Term. 15
without variation
ON
OFF
Term. 15
acceleration
OFF
ON
Term. 15
deceleration
ON
ON
-
deceleration and
inverter STOP
Term. 25
Term. 26
Rotation sense
Reaction
OFF
OFF
CW/CCW
without variation
ON
OFF
CW
acceleration
OFF
ON
CW
deceleration
OFF
ON
CCW
acceleration
OFF
ON
CCW
acceleration
ON
OFF
CCW
deceleration
ON
OFF
CW
acceleration
ON
ON
CW/CCW
deceleration and
inverter STOP
BERGES electronic
29.05.98
Operating manual ACM-D2
33
Содержание ACM-D2 0.37kW
Страница 1: ...Operating manual ACM ...
Страница 2: ......
Страница 29: ...14 9 Input circuit BERGES electronic 29 05 98 Operating manual ACM D2 27 ...
Страница 30: ...15 Programming ACM D2 15 1 Program structure BERGES electronic 28 Operating manual ACM D2 29 05 98 ...
Страница 31: ...BERGES electronic 29 05 98 Operating manual ACM D2 29 ...
Страница 61: ...20 Notes BERGES electronic 29 05 98 Operating manual ACM D2 59 ...
Страница 62: ...BERGES electronic ...
Страница 63: ......