Setting of the parameters
Use the DIL switch 05 to set desired parameters as
illustrated in Figure 2-21. The basic factory setting
is indicated.
NOTES
•
The function of the signal input
PWM/BOOST is defined by the
switch position of the Current con-
trol/Boost.
•
When current reduction is active the
motor phase current decreases to
70% in the idling condition (pulse fre-
quency <10 Hz). This leads to cool-
ing of the motor and reduction of the
stopping torque to approx. 70%.
•
The action of the DIRECTION signal
input can be inverted by means of
parameter switch 03 (direction of ro-
tation).
•
In the case of a half step the motor
executes 1000 steps per revolution,
in the case of a full step it performs
500 steps per revolution.
04
03
02
01
OFF
ON
1)
2)
05
PWM
active
inactive
right-
hand
2)
full step
half
step
left-
hand
2)
active
BOOST
active
Current control
1)
/
BOOST
Current reduction
Direction of rotation
Step size
Current control is by means of the PWM signal,
Current zero-setting is executed with a constant
high level of the PWM signal
when DIRECTION input is inactive
Figure 2-21 Settings of the parameter switch
Installation
WS5-5 Doc. no. 211.347/DGB 03.96
2 – 15
Содержание 64652810006
Страница 1: ...Power Drive WS5 5 Doc no 211 347 DGB 08 02 Ident No 00441108390 Edition b023 08 02 ...
Страница 4: ......
Страница 28: ...Installation 2 16 WS5 5 Doc no 211 347 DGB 03 96 ...
Страница 36: ...Errors Faults 4 4 WS5 5 Doc no 211 347 DGB 12 92 ...
Страница 37: ...5 Maintenance WS5 5 requires no maintenance Maintenance WS5 5 Doc no 211 347 DGB 12 92 5 1 ...
Страница 38: ...Maintenance 5 2 WS5 5 Doc no 211 347 DGB 12 92 ...