8.4
Problems, causes & solutions
Problem A :
The METOSWR does not wind up.
Cause
: Main switch is turned off
Solution
: Turn on the main switch (vertical)
Emergency stop locked
Release emergency stop (turn / pull out)
No supply voltage
Check the connection cable and power socket
Try another wall socket
Speed potentiometer at 0
Set a speed
Motor controller fault (green light blinking)
Turn the main switch off and on again
Hose blocked or too heavy (long)
Winding speed is too low,
set the speed control button faster
Other causes
Consult your dealer
Problem B :
Speed can be poorly adjusted.
Cause B
: Speed control button is defective.
Solution
: Consult your dealer
Winding up is too heavy
Winding speed is too low,
set the speed control button faster
Consult your dealer
Motor controller is defective
Consult your dealer
Problem C :
The automatic cut-off does not work.
Cause C
: The automatic cut-off point is not defined properly
Solution
: See 8.1.1 Preparing for use
Problem D :
Feed through coupler leaks.
Cause D
: Worn by prolonged use
Solution
: Renew the feed through coupler
Worn by other causes
Forgotten to flush the system
Use of aggressive chemicals
Renew the feed through coupler
Consult your dealer