7.7
Venting the system
For proper operation and a stable pressure and flow, the system must be vented before
use. To do this, proceed as follows:
Fill the tank with clean water via the filter in the tank lid (3)
In Settings (8.2.1), set to the desired spray pressure
In the manual control menu, select Spraying 1 and Wall spraying 1
Open the lower ball valves of both spray booms and press Start to flush the system
Ball valves open!
Keep the start button pressed until good jets of water flow out of the ball valves and
the pump is running at a constant speed
Close the ball valves
Fold up the spray booms (if retractable booms)
Open the top nozzles!
Open the top nozzles and press the start button again to vent the spray booms
Keep the start button pressed until a good spray comes out of the spray nozzles
Then turn the nozzles open at the height at which you want to spray and test by
pressing the start button to be sure that all nozzles produce a good spray
The
METO-SWT
is now vented and ready for use after having gone through chapter
8.